Connecting up
4.5 Signaling contact
SCALANCE XP-200
60
Operating Instructions, 05/2016, C79000-G8976-C428-01
4.5
Signaling contact
Information on the signaling contact
●
To connect the signaling contact, the device has an M12 interface: B-coded, 5-pin, male.
●
The signaling contact is a floating switch that signals error statuses by opening the
contact.
The signaling contact must be operated within the range of the operating voltage.
If an error/fault occurs, the signaling contact opens. In normal operation, the signaling
contact is closed.
●
To connect the signaling contact, use a copper cable of category 24 AWG or a cable with
a cross-section of
≥
0.25 mm
2
, see e.g. the section "Product overview (Page 17)".
NOTICE
Damage due to voltage being too high
You can load the signaling contact with the operating voltage of the device and a maximum
of 100 mA.
Higher voltages or currents can damage the device.
Position and assignment
Figure 4-3
Position of the signaling contact, for example on the SCALANCE XP208
Pin number
Contact
Assignment
1
F1
Fault contact 1
4
F2
Fault contact 2
Summary of Contents for SCALANCE XP-200
Page 8: ...Introduction SCALANCE XP 200 8 Operating Instructions 05 2016 C79000 G8976 C428 01 ...
Page 84: ...Dimension drawings SCALANCE XP 200 84 Operating Instructions 05 2016 C79000 G8976 C428 01 ...
Page 92: ...Approvals SCALANCE XP 200 92 Operating Instructions 05 2016 C79000 G8976 C428 01 ...