Connection
6.7 Replacing the PLUG (C-PLUG or KEY-PLUG)
SCALANCE W778-1 /W738-1
50
Operating Instructions, 07/2020, C79000-G8976-C450-06
Inserting a PLUG that does not contain the configuration of a compatible device type,
accidentally removing the PLUG/KEY-PLUG or general malfunctions of the PLUG are
signaled by the diagnostics mechanisms of the device (LEDs, Web-Based Management
(WBM), SNMP, Command Line Interface (CLI) and PROFINET diagnostics). The user
then has the choice of either removing the PLUG again or selecting the option to
reformat the PLUG.
Note
Incompatibility with previous versions with PLUG inserted
During the installation of a previous version of the firmware, the configuration data can
be lost. In this case, the device starts up with the factory settings after the firmware has
been installed. In this situation, if a PLUG is inserted in the device, following the restart,
this has the status "NOT ACCEPTED" since the PLUG still has the configuration data of
the previous more up-to-date firmware. This allows you to return to the previous, more
up-to-date firmware without any loss of configuration data. If the original configuration
on the PLUG is no longer required, the PLUG can be deleted or rewritten manually using
"System > PLUG".
Position
The PLUG slot is on the top of the device housing under a cover, see Reset key
(Page 27).
Removing the PLUG
Follow the steps below to remove a PLUG from the device:
1.
Turn off the power to the device.
2.
Release the screw of the slot cover and swing the slot cover to the side.
3.
Insert a screwdriver between the front edge of the PLUG (A) and the slot and release
the PLUG.
4.
Remove the PLUG from the slot.
5.
Close the cover (tightening torque 0.8 Nm), to ensure that the device is closed and
water and dust proof.