Description of the device
4.7 PLUG
SCALANCE W774-1 / W734-1
34
Operating Instructions, 03/2022, C79000-G8976-C325-15
4.7
PLUG
The PLUG is available in the following variants:
•
C-PLUG: The removable data storage medium only saves the configuration data of
the device.
•
KEY-PLUG: In addition to the configuration data, the removable data storage medium
contains a license with which special functions are enabled, e.g. iFeatures.
You will find the article numbers under Accessories (Page 22).
NOTICE
Do not remove or insert a C-PLUG / KEY-PLUG during operation!
A PLUG may only be removed or inserted when the device is turned off.
The device checks whether or not a PLUG is inserted at one second intervals. If it is
detected that the PLUG was removed, there is a restart.
If a KEY-PLUG was inserted in the device, the device changes to a defined error state
following the restart. With SCALANCE W, the available wireless interfaces are
deactivated in this case.
If the device was configured at some time with a PLUG, the device can no longer be
used without this PLUG. To be able to use the device again, reset the device to the
factory settings.
NOTICE
Loss of the degree of protection
When the cover is not mounted correctly, the device loses its degree of protection.
Position
The PLUG slot is on the top of the device housing under a cover, see Device description
(Page 20).
Summary of Contents for SCALANCE W734-1 RJ-45
Page 8: ...Introduction SCALANCE W774 1 W734 1 8 Operating Instructions 03 2022 C79000 G8976 C325 15 ...
Page 10: ...Safety notices SCALANCE W774 1 W734 1 10 Operating Instructions 03 2022 C79000 G8976 C325 15 ...
Page 66: ......
Page 76: ...Approvals SCALANCE W774 1 W734 1 76 Operating Instructions 03 2022 C79000 G8976 C325 15 ...
Page 78: ...Index SCALANCE W774 1 W734 1 78 Operating Instructions 03 2022 C79000 G8976 C325 15 ...