Siemens SCALANCE W700 802.11ax Reference Manual Download Page 2

 

 

 

 

Siemens AG 

Digital Industries 

Postfach 48 48 

90026 NÜRNBERG 

GERMANY 

C79000-G8976-C620-02 

 11/2021 Subject to change 

Copyright © Siemens AG 2021. 

All rights reserved 

Legal information 

Warning notice system 

This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent 

damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert 

symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are 

graded according to the degree of danger. 

 

DANGER 

indicates that death or severe personal injury 

will

 result if proper precautions are not taken. 

 

 

WARNING 

indicates that death or severe personal injury 

may

 result if proper precautions are not taken. 

 

 

CAUTION 

indicates that minor personal injury can result if proper precautions are not taken. 

 

 

NOTICE 

indicates that property damage can result if proper precautions are not taken. 

If more than one degree of danger is present, the warning notice representing the highest degree of danger will 

be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to 

property damage. 

Qualified Personnel 

The product/system described in this documentation may be operated only by 

personnel qualified

 for the specific 

task in accordance with the relevant documentation, in particular its warning notices and safety instructions. 

Qualified personnel are those who, based on their training and experience, are capable of identifying risks and 

avoiding potential hazards when working with these products/systems. 

Proper use of Siemens products 

Note the following: 

 

WARNING 

Siemens products may only be used for the applications described in the catalog and in the relevant technical 

documentation. If products and components from other manufacturers are used, these must be recommended 

or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and 

maintenance are required to ensure that the products operate safely and without any problems. The permissible 

ambient conditions must be complied with. The information in the relevant documentation must be observed. 

Trademarks 

All names identified by ® are registered trademarks of Siemens AG. The remaining trademarks in this publication 

may be trademarks whose use by third parties for their own purposes could violate the rights of the owner. 

Disclaimer of Liability 

We have reviewed the contents of this publication to ensure consistency with the hardware and software 

described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the 

information in this publication is reviewed regularly and any necessary corrections are included in subsequent 

editions. 

Summary of Contents for SCALANCE W700 802.11ax

Page 1: ...11ax OUTDATED TRANSLATION SIMATIC NET Industrial Wireless LAN Performance data SCALANCE W700 802 11ax Reference Manual 11 2021 C79000 G8976 C620 02 Security information 1 Frequency modulation 2 3 Transmit power 4 Data transmission speed ...

Page 2: ...ly by personnel qualified for the specific task in accordance with the relevant documentation in particular its warning notices and safety instructions Qualified personnel are those who based on their training and experience are capable of identifying risks and avoiding potential hazards when working with these products systems Proper use of Siemens products Note the following WARNING Siemens prod...

Page 3: ... G8976 C620 02 3 Table of contents 1 Security information 5 2 Frequency modulation 7 3 Data transmission speed 9 3 1 IEEE 802 11abg 9 3 2 IEEE 802 11n 10 3 3 IEEE 802 11ac 11 3 4 IEEE 802 11ax 12 4 Transmit power 13 4 1 Frequency band 2 4 GHz 13 4 2 Frequency band 5 GHz 14 ...

Page 4: ...Table of contents Performance data SCALANCE W700 802 11ax 4 Reference Manual 11 2021 C79000 G8976 C620 02 ...

Page 5: ...rise network or the internet if and to the extent such a connection is necessary and only when appropriate security measures e g firewalls and or network segmentation are in place For additional information on industrial security measures that may be implemented please visit https www siemens com industrialsecurity https www siemens com industrialsecurity Siemens products and solutions undergo con...

Page 6: ...Security information Performance data SCALANCE W700 802 11ax 6 Reference Manual 11 2021 C79000 G8976 C620 02 ...

Page 7: ...g n ax ISM band 2 412 GHz 2 472 GHz 11a n ac ax ISM band 5 180 GHz 5 825 GHz Modulation 802 11a OFDM BPSK QPSK 16 QAM 64 QAM 802 11b DSSS BPSK DQPSK CCK 802 11g OFDM BPSK QPSK 16 QAM 64 QAM 802 11n OFDM BPSK QPSK 16 QAM 64 QAM 802 11ac OFDM BPSK QPSK 16 QAM 64 QAM 128 QAM 256 QAM 802 11ax OFDM BPSK QPSK 16 QAM 64 QAM 128 QAM 256 QAM 1024 QAM ...

Page 8: ...Frequency modulation Performance data SCALANCE W700 802 11ax 8 Reference Manual 11 2021 C79000 G8976 C620 02 ...

Page 9: ...mission speed 0 2 1 IEEE 802 11abg The following table shows the data transmission speeds with 802 11a 802 11b and 802 11g Protocol Transmission speed in Mbps 802 11a 6 9 12 18 24 36 48 54 802 11b 1 2 5 5 11 802 11g 6 9 12 18 24 36 48 54 All transmission types support the automatic fallback function ...

Page 10: ... 1 6 5 7 2 13 5 15 0 1 1 13 0 14 4 27 0 30 0 2 1 19 5 21 7 40 5 45 0 3 1 26 0 28 9 54 0 60 0 4 1 39 0 43 3 81 0 90 0 5 1 52 0 57 8 108 0 120 0 6 1 58 5 65 0 121 5 135 0 7 1 65 0 72 2 135 0 150 0 8 2 13 0 14 4 27 0 30 0 9 2 26 0 28 9 54 0 60 0 10 2 39 0 43 3 81 0 90 0 11 2 52 0 57 8 108 0 120 0 12 2 78 0 86 7 162 0 180 0 13 2 104 0 115 6 216 0 240 0 14 2 117 0 130 0 243 0 270 0 15 2 130 0 144 4 270...

Page 11: ...0 117 0 130 0 4 1 39 0 43 3 81 0 90 0 175 5 195 0 5 1 52 0 57 8 108 0 120 0 234 0 260 0 6 1 58 5 65 0 121 5 135 0 263 3 292 5 7 1 65 0 72 2 135 0 150 0 292 5 325 0 8 1 78 0 86 7 162 0 180 0 351 0 390 0 9 1 180 0 200 0 390 0 433 3 0 2 13 0 14 4 27 0 30 0 58 5 65 0 1 2 26 0 28 9 54 0 60 0 117 0 130 0 2 2 39 0 43 3 81 0 90 0 175 5 195 0 3 2 52 0 57 8 108 0 120 0 234 0 260 0 4 2 78 0 86 7 162 0 180 0 ...

Page 12: ...3 8 1 103 2 97 5 87 8 206 5 195 0 175 5 432 4 408 3 367 5 9 1 114 7 108 3 97 5 229 4 216 7 195 0 480 4 453 7 408 3 10 1 129 0 121 9 109 7 258 1 243 8 219 4 540 4 510 4 459 4 11 1 143 4 135 4 121 9 286 8 270 8 243 8 600 5 567 1 510 4 0 2 17 2 16 3 14 6 34 4 32 5 29 3 72 1 68 1 61 3 1 2 34 4 32 5 29 3 68 8 65 0 58 5 144 1 136 1 122 5 2 2 51 6 48 8 43 9 103 2 97 5 87 8 216 2 204 2 183 8 3 2 68 8 65 0...

Page 13: ...s made according to the following scheme 1 antenna connection max transmit power Max conducted power 2 antenna connections max transmit power 3 dBm Max conducted power Protocol Transmission speed Max transmit power dBm Receiver sensitivity dBm 2 412 GHz 2 442 GHz 2 472 GHz 2 442 GHz 802 11g 6 Mbit s 20 20 20 92 12 Mbit s 20 20 20 89 54 Mbit s 20 20 20 75 802 11n HT20 MCS 0 20 20 20 90 MCS 7 20 20 ...

Page 14: ...ax conducted power 2 antenna connections max transmit power 3 dBm Max conducted power Protocol Transmission speed Max transmit power dBm Receiver sensitivity dBm 5 18 GHz 5 5 GHz 5 745 GHz 5 5 GHz 802 11a 6 Mbit s 20 20 20 90 12 Mbit s 20 20 20 87 54 Mbit s 20 20 17 74 802 11n HT20 MCS0 20 20 20 90 MCS7 20 20 17 71 802 11n HT40 MCS0 20 20 20 87 MCS7 20 20 17 68 802 11ac VHT20 MCS0 20 20 20 90 MCS8...

Reviews: