Socket outlet switch wave S 564 

5WG3 564-7AB11 

 

 

Siemens AG 

S 564, 4 pages 

Technical Manual 

Automation and Drives Group 

 

 

Electrical Installation Technology 

©

 Siemens AG 2005 

Update: http://www.siemens.de/gamma 

P.O. Box 10 09 53, D-93009 Regensburg 

Subject to change without prior notice 

 

 

2.20.7.1/3 

Commissioning: 
The connection e.g.  of a push button wave with the 
socket outlet switch wave is carried out by pressing the 
push button of the push button wave and the push but-
ton of the socket outlet switch wave. To do so, the spe-
cial function must be set for the two devices which have 
to be connected with each other. The operating state 
and the successful connection are displayed by the 
LEDs of both devices. 
 

Connection via radio control: 

Connecting a push button wave to a socket outlet switch 
wave via radio control: 
 

B1

B2

 

 
Figure 3: 
B1 push button wave 
B2 socket outlet switch wave 
 

1. Socket outlet switch wave: Switch to special func-

tion (B2) 

Action: Press the push button for at least 10 seconds. 
Display:  The LED begins to flash slowly (approx. once 

per second) after 10 seconds (switches to special 
function). 

 

2. Push button wave: Switch to special function (B1) 

Action: Press the push button rocker in the CENTRE for 

at least 10 seconds. 

Display:  The LED of the push button begins to flash 

slowly (approx. once per second) after 10 sec-
onds (toggling to the special function). 

3. Push button wave: Transmit a linking telegram (B1) 

Action: Brief operation (up to 0.4 sec.) of the push button 

rocker at the TOP, CENTRE or BOTTOM. 

Display:  The LED of the push button wave flashes rapidly 

(3 times per sec.) for approx. 3 seconds if the con-
nection has been established successfully. The 
LED is then extinguished and the push button ex-
its the special function. The LED of the socket out-
let switch wave flashes in the same way and the 
special function mode is terminated. 

 

Note: 

There is only a limited period available for the 

connection as both devices exit the special function after 
2 minutes. 
 

The connection of the socket outlet switch wave with the 
push button wave is complete. When the push button 
wave is operated the socket outlet switch wave will be 
switched as well via the radio connection. 
If the connection has failed (e.g. if the distance is too 
great), both devices exit the special function after 
approx. 2 minutes, without confirming the success of the 
connection by flashing rapidly. 
This procedure must be repeated if the socket outlet 
switch is to be connected with other push buttons or 
sensors (up to 10 connections possible). 
 

Procedure for deleting a connection: 

Single connections can be deleted by reconnecting an 
already known device. 
 
Deletion of the connection between a push button wave 
and the socket outlet switch wave: 
 

1.

 Socket outlet switch wave: Switch to the special func-

tion 

2.

 Push button wave: Switch to the special function 

3.

 Push button wave: Trigger a linking telegram 

 
The connection between the socket outlet switch wave 
and the push button wave is thereby deleted. 
 

Deleting all connections and resetting to the sup-
plied state: 
1.

 Switch the push button wave to the special function. 

Action: Press the push button for at least 10 seconds. 
Display:  The LED begins to flash slowly (approx. once 

per second) after 10 seconds (switches to the 
special function). 

 

2.

 Reset the device 

Action: Press the push button again for at least 10 sec-

onds. 

Display:  The LED of the push button flashes rapidly (3 

times per second) for approx. 3 seconds. The 
LED is then extinguished and the socket outlet 
switch wave exits the special function. 

 
 
All connections in this device are deleted. The device is 
restored to its initial state. 
Connections to the socket outlet switch wave in other 
devices are retained and must likewise be deleted. 
 
 
 
 
 
 
 
 

Summary of Contents for S 564

Page 1: ...g connections with other radio control com ponents Deleting connections with other radio control compo nents Operation After a short operation of the push button less than 10s the local socket outlet is switched ON or OFF respec tively After a long operation at least 10s the device is switched to special function mode In this mode the socket outlet switch wave can be connected with other devices o...

Page 2: ...c conditions EN 50090 2 2 Ambient operating temperature 5 45 C Storage temperature 25 70 C Relative humidity non condensing 5 to 93 Approbation VDE Approbation in preparation complies Standard radio frequency wave easy mode push button EP CE Norm Complies with EN 61058 1 DIN VDE 0620 DIN 49440 DIN 4944 EMV regulations residential building low voltage regulations and R TTE regulations The CE declar...

Page 3: ...ion The LED of the socket out let switch wave flashes in the same way and the special function mode is terminated Note There is only a limited period available for the connection as both devices exit the special function after 2 minutes The connection of the socket outlet switch wave with the push button wave is complete When the push button wave is operated the socket outlet switch wave will be s...

Page 4: ...state is terminated by the following actions and switched back to normal mode 1 Receipt of a linking telegram 2 Time out after 2 minutes no push button actions are carried out and no linking telegrams are received for a period of two minutes 3 Operation of the push button of the socket outlet switch wave for less than 10s Dimension Diagram Dimensions in mm 72 128 33 37 4 55 6 74 6 General informat...

Reviews: