Siemens S 564 Technical Manual Download Page 1

 

instabus EIB

 

Technical Product Information 

August 2005 

Socket outlet switch wave S 564  

5WG3 564-7AB11 

 

Siemens AG 

S 564, 4 pages 

Technical Manual 

Automation and Drives Group 

 

 

Electrical Installation Technology 

©

 Siemens AG 2005 

Update: http://www.siemens.de/gamma 

P.O. Box 10 09 53, D-93009 Regensburg 

Subject to change without prior notice 

 

 

2.20.7.1/1 

Product and Applications Description 

 

 

 
The socket outlet switch wave S 564 is an adapter plug 
for the remote control of electrical devices connected to 
socket outlets like floor lamps or radios by controlling a 
relay via radio frequency. 
The socket outlet switch wave is a product from the 
range of GAMMA wave devices and therefore uses the 
standardized KNX RF protocol. 
Besides the remote operation using RF switches (with 
function switching or scene control) or other RF sensors 
like smoke detectors or door contacts, the socket outlet 
switch wave can be controlled directly by a push button 
on the device. A LED indicates the actual switching 
status. 
 
The commissioning of the socket outlet switch wave is 
carried out without any additional means via push button 
actions (Easy mode Push Button: EP). 
 
There are two different operation modes for the socket 
outlet switch wave: 

 

Normal function 

  Operation of the integrated socket outlet locally 

 Remote operation of the integrated socket outlet via 

RF switches or other RF senders 

 

Special function 

  Establishing connections with other radio control com-

ponents 

 Deleting connections with other radio control compo-

nents 

 
 

Operation 

 
After a short operation of the push button (less than 10s) 
the local socket outlet is switched ON or OFF respec-
tively. 

After a long operation (at least 10s) the device is 
switched to special function mode. In this mode the 
socket outlet switch wave can be connected with other 
devices or an established connection can be released. 
If the push button is operated again long (at least 10s) 
while in special function mode, all connections with other 
devices will be deleted. 
 
 

Installation Instructions 
 

Caution: 

  The device may be used in interior installations in dry 

rooms only. 

 Occasionally the transmission range may be influ-

enced by structural conditions (e.g. reinforced con-
crete) or electric / electronic sources of interference. 

 A minimum distance of 0.5m must be maintained 

between the transmitter and the relevant receivers. 

 Though the radio transmission is carried out in the 

safe 868MHz range, disruptions to the radio transmis-
sion cannot be excluded. 

 The radio transmission is not suitable for security 

applications. 

 
 

V

 WARNING 

  The device must not be opened. 

 The device must not be combined with other adaptor 

plugs 

  The prevailing safety and accident regulations must be 

observed. 

 

 
Technical Specifications 

 

Mechanical specifications 

 Housing: plastic 

  Mounting form: socket outlet adapter for countries 

using socket outlets with side grounding contacts (DIN 
norm) 

  Dimensions (L x W x D): 

12,8 x 7,2 x 7,5 cm (incl. contacts) 

  Weight: approx. 140g 

 

Power supply 

Integrated power supply 230V AC +10% / -15% 
 
 
 
 

Summary of Contents for S 564

Page 1: ...g connections with other radio control com ponents Deleting connections with other radio control compo nents Operation After a short operation of the push button less than 10s the local socket outlet is switched ON or OFF respec tively After a long operation at least 10s the device is switched to special function mode In this mode the socket outlet switch wave can be connected with other devices o...

Page 2: ...c conditions EN 50090 2 2 Ambient operating temperature 5 45 C Storage temperature 25 70 C Relative humidity non condensing 5 to 93 Approbation VDE Approbation in preparation complies Standard radio frequency wave easy mode push button EP CE Norm Complies with EN 61058 1 DIN VDE 0620 DIN 49440 DIN 4944 EMV regulations residential building low voltage regulations and R TTE regulations The CE declar...

Page 3: ...ion The LED of the socket out let switch wave flashes in the same way and the special function mode is terminated Note There is only a limited period available for the connection as both devices exit the special function after 2 minutes The connection of the socket outlet switch wave with the push button wave is complete When the push button wave is operated the socket outlet switch wave will be s...

Page 4: ...state is terminated by the following actions and switched back to normal mode 1 Receipt of a linking telegram 2 Time out after 2 minutes no push button actions are carried out and no linking telegrams are received for a period of two minutes 3 Operation of the push button of the socket outlet switch wave for less than 10s Dimension Diagram Dimensions in mm 72 128 33 37 4 55 6 74 6 General informat...

Reviews: