Siemens RWB30 Installation Instructions Download Page 2

RWB30 Timeswitch

User Instructions

Using Override (Advance)

To advance the programme, that is to bring forward the next ON or OFF

period as shown in the example below, press the override button.
EXAMPLE:

  WITHOUT (OVERRIDE) ADVANCE

EXAMPLE:

WITH (OVERRIDE)  ADVANCE  AT 5.35 AM

Adjusting the Clock (Dial Time)

To set the clock to the correct time of day rotate the dial clockwise as

shown by the arrow so that the correct time is adjacent to the raised

line with time written against it. Please note the dial is a 24 hour dial

with times shown numerically at two hour intervals and bars for hours

between.

NB

Do not rotate the dial anti-clockwise as this could cause damage to

the mechanism.

Changing the ON/OFF Times

The RWB30 is supplied with factory settings (See 

Factory Settings

)

which will operate unless you change the set times:
If you wish to change the factory settings to your own times you can do

this easily:
No 1 tappet (orange) is the first ON during the 24 hour period

No 2 tappet (blue) is the first OFF during the 24 hour period

No 3 tappet (orange) is the second ON during the 24 hour

period

No 4 tappet (blue) is the second OFF during the 24 hour period
To set the tappets to your own programme times hold the dial and slide

the relevant tappet and rotate it in either direction to your desired time,

then rotate dial through a full 24 hour rotation.

NB

This should be carried out with the programmer connected and

power supply switched on to the backplate.

Power Failure

In the event of a mains power failure do not move the dial until power

has been restored. If accidentally the dial has been moved during a

power failure then rotate the dial through a full 24 hour rotation before

resetting to actual time.

TAPPET No.

1

2

COLOUR

ORANGE

BLUE

ON

OFF

TAPPET No.

2

COLOUR

BLUE

OFF

Using Boost

BOOST

Pressing this button once brings the unit ON for 1 hour.

To activate 

BOOST

 push the 

BOOST

 button.

NB

This feature operates in OFF, ONCE and TWICE modes

only.

EXAMPLE:

  BOOST PRESSED AT 12.00

EXAMPLE:

 BOOST PRESSED AT 8.00

TAPPET No.

1

OFF

3

4

COLOUR

ORANGE

ORANGE

BLUE

ON

ON

OFF

TAPPET No.

1

2

BOOST

3

4

COLOUR

ORANGE

BLUE

I HR

ORANGE

BLUE

ON

OFF

ON   OFF

ON

OFF

ALL DAY

 — The unit will switch ON at the morning ON and OFF at the

evening OFF.

EXAMPLE:

CONSTANT

 — Continuously ON

When the unit is in an ‘ON’ mode as above the LED lights for each

circuit will be on.

TAPPET No.

1

4

COLOUR

ORANGE

BLUE

Introduction

The RWB30 is an advanced daily timeswitch combining the benefits of

electronic reliability and ease of use with mechanical dial operation.

Please take time to read these operating instructions carefully.
For installation see the enclosed instructions.

Features

— Up to 2 ON/OFF periods per day.

— ADVANCE feature to bring forward the next ON or OFF period as

required.

— BOOST feature to give an immediate 1 hour ON period at any time.

— Remembers last condition (ie ON or OFF) in the event of power

failure.

— Volt free contacts suitable for combination boilers.

Factory Settings

Before leaving the factory your RWB30 was programmed to switch your

system ON and OFF at the following times:

ON at 6.00 a.m.

OFF at 8.30 a.m.

ON at 4.30 p.m.

OFF at 10.30 p.m.

To activate this base programme:
Set clock dial to correct time. See 

Adjusting the Clock (Dial Time)

.

Operating Controls

All controls for daily use are located on and to the right hand side of the
dial.

Setting the Switching Programme

To make your selection slide the selector so that the vertical mark is

pointing to the desired position as below.

OFF

 — Continuously OFF.

TWICE

 — The unit will switch ON and OFF according to the morning

and evening settings.

EXAMPLE:

TAPPET No.

1

2

3

4

COLOUR

ORANGE

BLUE

ORANGE

BLUE

ON

OFF

ON

OFF

Reviews: