Chapter 2
Installing the Base Station
RUGGEDCOM WIN7225
Installation Guide
10
Mounting the Base Station
II 3 G nA IIC T4 X
P/N: WiN72XX-Y
Pico Base Station
S/N:
XXXXWWYYXXX
WARNING - EXPLOSION HAZARD
DO NOT SEPARATE WHILE CIRCUIT IS LIVE
UNLESS AREA IS KNOWN TO BE SAFE
AVERTISSEMENT - RISQUE D'EXPLOSION
NE PAS DÉBRANCHER TANT QUE LE CIRCUIT EST SOUS TENSION,
À MOINS QU'IL NE S'AGISSE D'UN EMPLACEMENT NON DANGEREUX
Rating: DC 48V, 1A
Class I Division 2 Groups A,B,C,D
T4
Figure 2: Compliance Label (Example)
Section 2.5
Mounting the Base Station
The base station is designed to be mounted to a wall, pole or tower.
DANGER!
Electrocution hazard – risk of death or serious injury. Make sure the distance between the base station
and nearby power lines meets the minimum requirements established by local standards.
CAUTION!
Crushing hazard – risk of death, serious personal injury and/or equipment damage. Make sure the wall,
pole or tower can support the weight of the base station. For more information, refer to
NOTE
For detailed dimensions of the base station, refer to
Section 4.7, “Dimension Drawings”
CONTENTS
•
Section 2.5.1, “Mounting the Base Station to a Wall or Tower”
•
Section 2.5.2, “Mounting the Base Station to a Pole”
•
Section 2.5.3, “Assembling the Base Station and Mounting Bracket”
Section 2.5.1
Mounting the Base Station to a Wall or Tower
Mount the base station to any wall or tower capable of supporting its weight. An outer wall on a roof or other high
location to avoid interference from other buildings or trees is preferred.
To mount the base station to a wall or tower, do the following: