CSA
•
UL 1604
Electrical Equipment for Use in Class I and II, Division 2, and Class III Hazardous (Classified) Locations
•
CAN/CSA-C22.2 No. 213-M1987
Non-Incendive Electrical Equipment for Use in Class I, Division 2 Hazardous Locations
The subscriber station is marked with an MET classified mark that indicates compliance with both Canadian and
U.S. requirements.
It is specifically approved for use in hazardous locations defined as:
• Class I, Division 2, Groups A, B, C, D T4
• Ex nA nC IIC T4 Gc
• Class I, Zone 2, AEx/Ex nA nC IIC T4 Gc
Notices specific to MET Laboratories:
WARNING!
EXPLOSION HAZARD
• Substitution of components may impair suitability for Class I, Division 2
• Do not disconnect equipment unless power has been switched off or the area is known to be non-
hazardous
• Use only Lambda DPP50-48 Power Supply in conjunction with the unit
AVERTISSEMENT !
RISQUE D’EXPLOSION
• La substitution decomposants peut rendre ce matériel inacceptable pour les emplacements de Classe
I, Division 2
• Avant de déconnecter l’equipment, couper le courant ou s’assurer que l’emplacement est désigné
non dangereux
• Utilisez l’unité uniquement avec une batterie de la marque Lamba DPP50-48
Section 5.1.2
CSA
This subscriber station meets the requirements of the following Canadian Standards Association (CSA) standards:
•
CAN/CSA-C22.2 No. 60950-1-07+A1:2011+A2:2014
Information Technology Equipment – Safety – Part 1: General Requirements (Bi-National Standard, with UL
60950-1)
•
CAN/CSA-C22.2 No. 60950-22-07+GI1:2012
Information Technology Equipment – Safety – Part 22: Equipment to be Installed Outdoors (Bi-National
standard, with UL 60950-22)