Chapter 2
Installing the Subscriber Station
RUGGEDCOM WIN5237
Installation Guide
24
Applying Self-Amalgamating Tape
2. Reconnect the cable and slide the tube up to meet the subscriber station chassis.
3. Hold the tube against the subscriber station chassis and start rotating it clockwise while gently pulling out the
core. Stop rotating once the front end of the cold shrink has begun to form around the cable end.
4. Continue to remove the core in a counter-clockwise direction until it is completely removed.
Section 2.9.3
Applying Self-Amalgamating Tape
To apply self-amalgamating (or self-fusing) tape to a cable end, do the following:
IMPORTANT!
When applying self-amalgamating tape, make sure to stretch it to 2/3 of its original width to form a
tight seal.
1. Cut a strip of self-amalgamating tape approximately 50 cm (19.7 in) long.
2. Apply one end of the tape to the cable end and tightly wrap it around the cable once fully, making sure the
tape overlaps.
3. Tightly wrap the remainder of the tape down the cable, making sure the tape overlaps with each pass.
4. Repeat the previous steps to apply a second layer of tape.
Section 2.10
Configuring the Subscriber Station
Once the subscriber station is installed and connected to the network, it must be configured. The RUGGEDCOM
WIN5237 features a Web-based User Interface (UI) for all configuration management. For more information about
configuring the subscriber station, refer to the
RUGGEDCOM WIN Subscriber Station User Guide
associated with
the subscriber station and the installed software release.