RUGGEDCOM RX1000P
Installation Guide
Chapter 2
Installing the Device
Wiring Examples
11
4
2
1
3
4
6
5
7
4
6
4
3
6
5
7
4
6
5
Figure 6: Terminal Block Wiring
1.
Screw-Type Terminal Block
2.
Pluggable Terminal Block
3.
Jumper
4.
Positive/Live (+/L) Terminal
5.
Negative/Neutral (-/N)
Terminal
6.
Surge Ground Terminal
7.
Chassis Ground Terminal
4. Connect the negative wire from the power source to the negative/neutral (-/N) on the terminal block. For
Section 2.2.3, “Wiring Examples”
5. Install the supplied metal jumper between terminals 2, 4 and 6 to connect the surge ground terminals to the
chassis ground terminal. The surge ground terminals are used as the ground conductor for all surge and
transient suppression circuitry internal to the unit.
6. Connect the ground terminal on the power source to the chassis ground terminal on the device. For more
Section 2.4, “Grounding the Device”
DANGER!
Electrocution hazard – risk of death, serious personal injury and/or damage to the device. Make
sure the supplied terminal block cover is always installed before the device is powered.
7. Install the terminal block cover.
Section 2.2.3
Wiring Examples
The following illustrate how to connect power to single and dual power supplies.