Technical Specifications
5.2 Failsafe Alarm Relay Specifications
5.2
Failsafe Alarm Relay Specifications
Hazardous Environments
Maximum Switching Voltage
Rated
Switching
Current
Isolation
30 VDC
2 A
5.0 kVAC
between coil and contacts
1.0 kVAC
between contacts
250 VAC
2 A
5.0 kVAC
between coil and contacts
1.0 kVAC
between contacts
50 to 60 Hz for 1 minute
Non-Hazardous Environment
Maximum Switching Voltage
Rated
Switching
Current
Isolation
30 VDC
2 A
5.0 kVAC
between coil and contacts
1.0 kVAC
between contacts
250 VAC
2 A
5.0 kVAC
between coil and contacts
1.0 kVAC
between contacts
50 to 60 Hz for 1 minute
5.3
Supported Networking Standards
The following networking standards are supported by RUGGEDCOM RSG910C:
Standard
10 Mbps
Ports
100 Mbps
Ports
1000 Mbps Ports
Notes
IEEE 802.3x
•
•
•
Full Duplex Operation
IEEE 802.3z
•
1000Base-LX
IEEE 802.3ab
•
1000Base-Tx
IEEE 802.1D
•
•
•
MAC Bridges
IEEE 802.1Q
•
•
•
VLAN (Virtual LAN)
IEEE
802.1Q-2005
•
•
•
Multiple Spanning
Tree Protocol (MSTP)
IEEE 802.1w
•
•
•
Rapid Spanning
Tree Protocol (RSTP)
IEEE 802.1p
•
•
•
Priority Levels
IEEE 802.1x
•
•
•
Port-based network
access control
IEEE 802.3
•
10Base-T
IEEE 802.3ad
•
•
•
Link aggregation
IEEE 802.3u
•
100Base-TX/100Base-FX
26
RUGGEDCOM RSG910C
Installation Manual, 04/2022, C79000-G8976-1405-11