Certification
6.2 EMC and Environmental Type Tests
•
EN50121-4
Railway applications – Electromagnetic Compatibility – Emission and Immunity
of the Signaling and Telecommunications Apparatus
•
EN50121-3-2
Railway applications – Electromagnetic Compatibility – Rolling Stock Apparatus
•
EN 50155
Railway applications – Rolling stock – Electronic equipment
6.2
EMC and Environmental Type Tests
The RUGGEDCOM RSG909R has passed the following Electromagnetic Compatibility
(EMC) and environmental tests.
EMC Type Tests
Test
Description
Test Levels
Severi-
ty Levels
Enclosure
Contact
± 8 kV
4
IEC
61000-4-2
ESD
Enclosure Air
± 15 kV
4
IEC
61000-4-3
Radiated RFI
Enclo-
sure Ports
20 V/m
Signal Ports
± 4 kV @ 2.5 kHz, 5 kHz
4
DC Pow-
er Ports
± 4 kV @ 2.5 kHz, 5 kHz
4
AC Pow-
er Ports
± 4 kV @ 2.5 kHz, 5 kHz
4
IEC
61000-4-4
Burst (Fast Transient)
Earth
Ground Ports
± 4 kV @ 2.5 kHz, 5 kHz
4
Signal Ports
± 4 kV Line-to-Ground
± 2 kV Line-to-Line
4
DC Pow-
er Ports
± 2 kV Line-to-Ground
± 1 kV Line-to-Line
3
IEC
61000-4-5
Surge
AC Pow-
er Ports
± 4 kV Line-to-Ground
± 2 kV Line-to-Line
4
Signal Ports
10 V
3
DC Pow-
er Ports
10 V
3
AC Pow-
er Ports
10 V
3
IEC
61000-4-6
Induced (Conducted) RFI
Earth
Ground Ports
10 V
3
IEC
61000-4-8
Magnetic Field
Enclo-
sure Ports
100 A/m Continuous
1000 A/m for 1 s
40
RUGGEDCOM RSG909R
Installation Manual, 02/2020, C79000-G8976-1388-09