Chapter 3
Modules
RUGGEDCOM RSG2488
Installation Guide
30
Installing/Removing Power Modules
3
1
2
Figure 19: Installing a Module
1.
Module
2.
Chassis
3.
Screw
5. Tighten the screws to secure the module.
6. [Optional] If necessary, install the device in the rack.
7. Connect power to the device.
Section 3.3
Installing/Removing Power Modules
The RUGGEDCOM RSG2488 supports dual redundant power supply modules.
CAUTION!
Contamination hazard – risk of equipment damage. Prevent the ingress of water, dirts and other debris
that may lead to premature equipment failure. Always make sure slots are not left empty.
NOTE
Power modules are hot swappable. When installing/removing a power module, it is not necessary to
turn off power to the redundant power module.
Removing a Power Module
To remove a power module, do the following:
1. Loosen the screws that secure the module to the chassis until the module can be removed.
2. Slide the module out of the chassis.