RUGGEDCOM RS950G
Installation Guide
Chapter 3
Device Management
Connecting to the Device
15
Device Management
This section describes how to connect to and manage the device.
CONTENTS
•
Section 3.1, “Connecting to the Device”
Section 3.1
Connecting to the Device
The following describes the various methods for accessing the ROS console and Web interfaces on the device. For
more detailed instructions, refer to the
ROS User Guide
for the RUGGEDCOM RS950G.
Serial Console Port
Connect a PC or terminal directly to the serial console port to access the boot-time control and ROS console
interface.
IMPORTANT!
The serial console port is intended to be used only as temporary connections during initial
configuration or troubleshooting.
The serial console port implements RS-232 DCE (Data Communication Equipment) on a DB9 connector. The
following is the pin-out for the port:
5
9
6
1
Figure 10: Serial DB9 Console Port
Pin
Name
Description
1
DCD
Data Carrier Detect
2
RX
Receive Data
3
TX
Transmit Data
4
DTR
Data Terminal Ready
5
GND
Signal Ground
6
DSR
Data Set Ready
7
RTS
Request to Send
8
CTS
Clear To Send
9
Reserved (Do Not Connect)
Summary of Contents for RUGGEDCOM RS950G
Page 4: ...RUGGEDCOM RS950G Installation Guide iv ...
Page 10: ...Preface RUGGEDCOM RS950G Installation Guide x Customer Support ...
Page 30: ...Chapter 4 Communication Ports RUGGEDCOM RS950G Installation Guide 20 SFP Transceivers ...
Page 36: ...Chapter 5 Technical Specifications RUGGEDCOM RS950G Installation Guide 26 Dimension Drawings ...