Chapter 6
Certification
RUGGEDCOM RS920W
Installation Guide
32
EMC and Environmental Type Tests
Test
Description
Test Levels
Severity Levels
DC Power Ports
± 4 kV
4
AC Power Ports
± 4 kV
4
Earth
Ground Ports
± 4 kV
4
Signal Ports
± 4 kV Line-to-Ground
± 2 kV
4
DC Power Ports
± 2 kV Line-to-Ground
± 1 kV Line-to-Line
3
IEC 61000-4-5
Surge
AC Power Ports
± 4 kV Line-to-Ground
± 2 kV Line-to-Line
4
Signal Ports
10 V
3
DC Power Ports
10 V
3
AC Power Ports
10 V
3
IEC 61000-4-6
Induced (Conducted) RFI
Earth
Ground Ports
10 V
3
IEC 61000-4-8
Magnetic Field
Enclosure Ports
40 A/m Continuous
1000 A/m for 1 s
IEC 61000-4-11
Voltage Dips and Interrupts
AC Power Ports
100% for 5 Periods
100% for 50 Periods
Signal Ports
2.5 kV Common Mode @ 1 MHz
1 kV Differential Mode @ 1 MHz
3
DC Power Ports
2.5 kV Common Mode @ 1 MHz
1 kV Differential Mode @ 1 MHz
3
IEC 61000-4-12
Damped Oscillatory
AC Power Ports
2.5 kV Common Mode @ 1 MHz
1 kV Differential Mode @ 1 MHz
3
Signal Ports
30 V Continuous
300 V for 1 s
4
IEC 61000-4-16
Mains Frequency Voltage
DC Power Ports
30 V Continuous
300 V for 1 s
4
IEC 61000-4-17
Ripple on DC Power Supply
DC Power Ports
10%
3
IEC 61000-4-29
Voltage Dips and Interrupts
DC Power Ports
30% for 0.1 s
60% for 0.1 s
100% for 0.05 s
Signal Ports
2 kV (Failsafe Relay Output)
DC Power Ports
1.5 kV
Dielectric Strength
AC Power Ports
2 kV
Signal Ports
5 kV (Failsafe Relay Output)
IEC 60255-5
HV Impulse
DC Power Ports
5 kV
Summary of Contents for RUGGEDCOM RS920W
Page 4: ...RUGGEDCOM RS920W Installation Guide iv ...
Page 10: ...Preface RUGGEDCOM RS920W Installation Guide x Customer Support ...
Page 32: ...Chapter 4 Communication Ports RUGGEDCOM RS920W Installation Guide 22 Serial Ports ...
Page 38: ...Chapter 5 Technical Specifications RUGGEDCOM RS920W Installation Guide 28 Dimension Drawings ...