Chapter 5
Technical Specifications
RUGGEDCOM RS900F
Installation Guide
28
Operating Environment
Section 5.5
Operating Environment
The RUGGEDCOM RS900F is rated to operate under the following environmental conditions.
Ambient Operating Temperature
k
-40 to 85 °C (-40 to 185 °F)
Ambient Storage Temperature
-40 to 85 °C (-40 to 185 °F)
Ambient Relative Humidity
l
5% to 95%
Maximum Altitude
2000 m
k
Measured from a 30 cm (12 in) radius surrounding the center of the enclosure.
l
Non-condensing.
Section 5.6
Mechanical Specifications
Weight
1.2 kg (2.7 lbs)
Ingress Protection
IP30
Enclosure
20 AWG Galvanized Steel
Section 5.7
Dimension Drawings
NOTE
All dimensions are in millimeters, unless otherwise stated.