RUGGEDCOM RS416P
Installation Guide
Chapter 1
Introduction
Supported Fiber Optic Cables
5
Siemens also does not recommend using copper Ethernet ports to interface with devices in the field across
distances that could produce high levels of ground potential rise (i.e. greater than 2500 V), during line-to-ground
fault conditions.
CONTENTS
•
Section 1.5.1, “Supported Fiber Optic Cables”
Section 1.5.1
Supported Fiber Optic Cables
The following fiber optic cable types are supported under the stated conditions.
Distance (m)
Cable Type
Wavelength (nm)
Modal Bandwidth
(MHz·km)
100Base-FX
1000Base-SX
10GBase-SR
850
200
—
275
33
OM1 (62.5/125)
1300
500
2000
—
—
850
500
—
550
82
OM2 (50/125)
1300
500
2000
—
—
850
1500
—
550
300
OM3 (50/125)
a
1300
500
2000
—
—
850
3500
—
550
400
OM4 (50/125)
a
1300
500
2000
—
—
a
Laser optimized.
Section 1.6
Precision Time Protocol (PTP) Support
The Precision Time Protocol (PTP) module adds the ability to provide time synchronization via Ethernet using the
Precision Time Protocol (PTP) and Network Time Protocol (NTP), and to synchronize with an external IRIG-B source.
The PTP module features BNC ports for TTL IN and TTL OUT. It also includes an LED to indicate when
synchronization has been achieved.
NOTE
The PTP module can only be installed in slot 5. For more information, refer to
Summary of Contents for RUGGEDCOM RS416P
Page 4: ...RUGGEDCOM RS416P Installation Guide iv ...
Page 10: ...Preface RUGGEDCOM RS416P Installation Guide x Customer Support ...
Page 18: ...Chapter 1 Introduction RUGGEDCOM RS416P Installation Guide 8 IEEE 1588 Support ...
Page 30: ...Chapter 2 Installing Device RUGGEDCOM RS416P Installation Guide 20 Wiring Examples ...
Page 48: ...Chapter 5 Technical Specifications RUGGEDCOM RS416P Installation Guide 38 Dimension Drawings ...