Certification
6.1.8 RoHS
6.1.8
RoHS
This device is declared by Siemens AG to meet the requirements of the following
RoHS (Restriction of Hazardous Substances) directives for the restricted use of certain
hazardous substances in electrical and electronic equipment:
•
China RoHS 2
Administrative Measure on the Control of Pollution Caused by Electronic
Information Products
A copy of the Material Declaration is available online at
support.industry.siemens.com/cs/ww/en/view/109738831
.
6.2
EMC and Environmental Type Tests
The RUGGEDCOM RS1600 has passed the following EMC and environmental tests.
EMC Type Tests per IEC 61850-3
Test
Description
Test Levels
Severity
Levels
Enclosure
Contact
± 8 kV
4
IEC 61000-4-2
ESD
Enclosure Air
± 15 kV
4
IEC 61000-4-3
Radiated RFI
Enclosure Ports
20 V/m
x
Signal Ports
± 4 kV @ 2.5 kHz
x
DC Power Ports
± 4 kV
4
AC Power Ports
± 4 kV
4
IEC 61000-4-4
Burst (Fast
Transient)
Earth
Ground Ports
± 4 kV
4
Signal Ports
± 4 kV Line-to-Earth,
± 2 kV Line-to-Line
4
DC Power Ports
± 2 kV Line-to-Earth,
± 1 kV Line-to-Line
3
IEC 61000-4-5
Surge
AC Power Ports
± 4 kV Line-to-Earth,
± 2 kV Line-to-Line
4
Signal Ports
10 V
3
DC Power Ports
10 V
3
AC Power Ports
10 V
3
IEC 61000-4-6
Induced
(Conducted)
RFI
Earth
Ground Ports
10 V
3
IEC 61000-4-8 Magnetic Field Enclosure Ports
40 A/m Continuous,
1000 A/m for 1 s
DC Power Ports
30% for 0.1 s, 60% for
0.1 s, 100% for 0.05 s
IEC 61000-4-29
Voltage Dips
and Interrupts
AC Power Ports
30% for 1 Period,
60% for 50 Periods
30
RUGGEDCOM RS1600
Installation Manual, 01/2021, C79000-G8976-1013-03