Chapter 4
Device Management
RUGGEDCOM ROX II
CLI User Guide
94
Managing Line Modules
3. Type
commit
and press
Enter
to save the changes, or type
revert
and press
Enter
to abort.
Section 4.16
Managing Line Modules
RUGGEDCOM RX5000/MX5000/MX5000RE devices feature slots for field-replaceable line modules, which can be
used to expand and customize the capabilities of the device to suit specific applications. A variety of modules are
available, each featuring a specific type of communication port. For information about available line modules,
refer to the
Modules Catalog
for the device family.
This section describes how to properly remove, install and configure line modules.
CONTENTS
•
Section 4.16.1, “Removing a Line Module”
•
Section 4.16.2, “Installing a New Line Module”
•
Section 4.16.3, “Viewing a List of Line Module Configurations”
•
Section 4.16.4, “Configuring a Line Module”
Section 4.16.1
Removing a Line Module
To remove a line module from the chassis, do the following:
1. Shut down the device. The device will shutdown for a period of time before rebooting and restarting. The
default time-out period is 300 seconds (five minutes). If more time is required to complete the procedure,
disconnect power from the device during the time-out period. For more information on how to shutdown the
device, refer to
Section 4.4, “Shutting Down the Device”
.
2. Remove the line module from the device.
Section 4.16.2
Installing a New Line Module
Line modules are hot-swappable and can be replaced with modules of the same type without powering down the
device.
To install a new line module in the chassis, do the following:
1. Make sure the CLI is in Configuration mode.
2. Set the module type to
none
by typing:
chassis
line-modules line-module
slot
module-type none
Where
slot
is the name of the module location.
3. Type
commit
and press
Enter
to save the changes, or type
revert
and press
Enter
to abort.
4. Insert the new line module into the empty slot in the chassis.
5. Reboot the device. For more information, refer to
Summary of Contents for RUGGEDCOM ROX II
Page 2: ...RUGGEDCOM ROX II CLI User Guide ii ...
Page 4: ...RUGGEDCOM ROX II CLI User Guide iv ...
Page 39: ...RUGGEDCOM ROX II CLI User Guide Table of Contents xxxix 19 5 VLANs 752 ...
Page 40: ...Table of Contents RUGGEDCOM ROX II CLI User Guide xl ...
Page 46: ...Preface RUGGEDCOM ROX II CLI User Guide xlvi Customer Support ...
Page 170: ...Chapter 5 System Administration RUGGEDCOM ROX II CLI User Guide 124 Deleting a Scheduled Job ...
Page 256: ...Chapter 6 Security RUGGEDCOM ROX II CLI User Guide 210 Enabling Disabling a Firewall ...
Page 402: ...Chapter 11 Wireless RUGGEDCOM ROX II CLI User Guide 356 Managing Cellular Modem Profiles ...