Chapter 7
Examples
RUGGEDCOM NETCONF
Reference Guide
100
Configuring OSPF Area and Network on a Layer 3 Device
</lock>
</rpc>]]>]]>
4. Configure the
<ip-address-src>
setting for the port:
<rpc message-id="233" xmlns="urn:ietf:params:xml:ns:netconf:base:1.0">
<edit-config>
<target>
<candidate/>
</target>
<config>
<interface xmlns="http://ruggedcom.com/ns/rmf_if">
<eth>
<slot>lm4</slot>
<port>1</port>
<ip-address-src>dynamic</ip-address-src>
</eth>
</interface>
</config>
</edit-config>
</rpc>]]>]]>
5. Commit the changes:
<rpc message-id="234" xmlns="urn:ietf:params:xml:ns:netconf:base:1.0">
<commit/>
</rpc>]]>]]>
6. Unlock the candidate configuration:
<rpc xmlns="urn:ietf:params:xml:ns:netconf:base:1.0" message-id="235">
<unlock>
<target>
<candidate/>
</target>
</unlock>
</rpc>]]>]]>
7. Unlock the running configuration:
<rpc xmlns="urn:ietf:params:xml:ns:netconf:base:1.0" message-id="236">
<unlock>
<target>
<running/>
</target>
</unlock>
</rpc>]]>]]>
Section 7.25
Configuring OSPF Area and Network on a Layer 3
Device
In this example, multiple
<rpc>
requests configure OSPF area and network in the candidate configuration and
then commit the changes.
The following is the recommended procedure for making configuration changes on a device.
1. Lock the running configuration:
<rpc xmlns="urn:ietf:params:xml:ns:netconf:base:1.0" message-id="230">
Summary of Contents for RUGGEDCOM MX5000RE
Page 8: ...Table of Contents RUGGEDCOM NETCONF Reference Guide viii ...
Page 12: ...Preface RUGGEDCOM NETCONF Reference Guide xii Customer Support ...
Page 26: ...Chapter 1 Introduction RUGGEDCOM NETCONF Reference Guide 14 Sample Session Editing Data ...
Page 40: ...Chapter 3 NETCONF Sessions RUGGEDCOM NETCONF Reference Guide 28 Killing a Session ...
Page 64: ...Chapter 5 Changing Configuration Data RUGGEDCOM NETCONF Reference Guide 52 Committing Changes ...
Page 148: ...Chapter 8 NETCONF XML Elements RUGGEDCOM NETCONF Reference Guide 136 validate ...