Section 5.1
Failsafe Relay Specifications
Maximum Switching Voltage
Rated Switching Current
Isolation
30 VDC
2 A, 60 W
125 VDC
0.24 A, 30 W
125 VAC
0.5 A, 62.5 W
220 VDC
0.24 A, 60 W
250 VAC
0.25 A, 62.5 W
1500 V
rms
for 1 minute
Section 5.2
Operating Environment
The RUGGEDCOM MX5000 is rated to operate under the following environmental conditions.
Ambient Operating Temperature
a
-40 to 85 °C (-40 to 185 °F)
Ambient Storage Temperature
-40 to 85 °C (-40 to 185 °F)
Ambient Relative Humidity
b
5% to 95%
Maximum Altitude
2000 m (6562 ft)
a
Measured from a 30 cm (12 in) radius surrounding the center of the enclosure.
b