Chapter 1
Introduction
RUGGEDCOM M969F
Installation Guide
6
Supported Fiber Optic Cables
Siemens also does not recommend using copper Ethernet ports to interface with devices in the field across
distances that could produce high levels of ground potential rise (i.e. greater than 2500 V), during line-to-ground
fault conditions.
CONTENTS
•
Section 1.4.1, “Supported Fiber Optic Cables”
Section 1.4.1
Supported Fiber Optic Cables
The following fiber optic cable types are supported under the stated conditions.
Distance (m)
Cable Type
Wavelength (nm)
Modal Bandwidth
(MHz·km)
100Base-FX
1000Base-SX
10GBase-SR
850
200
—
275
33
OM1 (62.5/125)
1300
500
2000
—
—
850
500
—
550
82
OM2 (50/125)
1300
500
2000
—
—
850
1500
—
550
300
OM3 (50/125)
a
1300
500
2000
—
—
850
3500
—
550
400
OM4 (50/125)
a
1300
500
2000
—
—
a
Laser optimized.
Section 1.5
Tamper-Evident Security Seals
In compliance with the security requirements of the Federal Information Processing Standards (FIPS140-2), FIPS-
compliant tamper-evident security seals are applied to potential access points on this device. Security seals provide
evidence of unauthorized tampering or removal of components.
IMPORTANT!
Worn, damaged or missing seals must be replaced immediately.
Replacement seals are available for purchase from Siemens. For more information, contact a Siemens
Sales representative.
There are three ways to determine if a security seal has been tampered with:
• The seal is cut or torn
• A pattern is left on the device when the top layer of the seal is removed
• Residue left by the seal is visible on the device under ultra-violet light
For information about the placement of security seals, refer to the
RUGGEDCOM ROS FIPS 140-2 Non-Proprietary
[https://support.industry.siemens.com/cs/ww/en/view/109757984]
.
Summary of Contents for RUGGEDCOM M969F
Page 4: ...RUGGEDCOM M969F Installation Guide iv ...
Page 10: ...Preface RUGGEDCOM M969F Installation Guide x Customer Support ...
Page 18: ...Chapter 1 Introduction RUGGEDCOM M969F Installation Guide 8 Decommissioning and Disposal ...
Page 38: ...Chapter 5 Technical Specifications RUGGEDCOM M969F Installation Guide 28 Dimension Drawings ...
Page 48: ...Chapter 6 Accessories RUGGEDCOM M969F Installation Guide 38 LC Fiber Optic 2 unit ...