Chapter 4
Technical Specifications
RUGGEDCOM M969
Installation Guide
22
Copper Ethernet Port Specifications
Maximum Switching Voltage
Rated Switching Current
Isolation
250 VAC
0.25 A, 62.5 W
Section 4.3
Copper Ethernet Port Specifications
Data Port
10/100 Mbps
Media
CAT-5 UTP or STP
Distance
100 m (328 ft)
Connector Type
RJ45 or M12
Section 4.4
Fiber Optic Ethernet Port Specifications
For maximum flexibility, Siemens offers a number of different transceiver choices for fiber optical
communications.
CONTENTS
•
Section 4.4.1, “Fast Ethernet Optical Specifications”
•
Section 4.4.2, “Gigabit Ethernet Optical Specifications”
Section 4.4.1
Fast Ethernet Optical Specifications
Mode
Connector
Cable
Type (µm)
Tx λ (nm)
c
Tx Pwr
(dBm)
(Min/Max)
Rx
Sensitivity
(dBm)
Rx
Saturation
(dBm)
Typical
Distance
(km)
Power
Budget (dB)
SM
LC
9/125
1300
-15/-8
-32
-3
20
17
SM
LC
9/125
1300
-5/0
-35
3
50
30
SM
LC
9/125
1300
0/5
-37
0
90
37
MM
LC
50/125
850
-22.5/-14
-31
-14
2
8.5
c
Typical.
Summary of Contents for RUGGEDCOM M969
Page 4: ...RUGGEDCOM M969 Installation Guide iv ...
Page 14: ...Chapter 1 Introduction RUGGEDCOM M969 Installation Guide 6 Description ...
Page 24: ...Chapter 2 Installing the Device RUGGEDCOM M969 Installation Guide 16 Ingress Protection ...
Page 44: ...Chapter 6 Accessories RUGGEDCOM M969 Installation Guide 36 LC Fiber Optic 2 unit ...