RUGGEDCOM M2200
Installation Guide
Chapter 5
Technical Specifications
Power Supply Specifications
25
Technical Specifications
This section details the specifications and operating conditions of the device.
CONTENTS
•
Section 5.1, “Power Supply Specifications”
•
Section 5.2, “Failsafe Relay Specifications”
•
Section 5.3, “Supported Networking Standards”
•
Section 5.4, “Copper Ethernet Port Specifications”
•
Section 5.5, “Fiber Optic Ethernet Port Specifications”
•
Section 5.6, “Operating Environment”
•
Section 5.7, “Mechanical Specifications”
•
Section 5.8, “Dimension Drawings”
Section 5.1
Power Supply Specifications
The RUGGEDCOM M2200 can be equipped with the following power supplies:
CAUTION!
Electrical hazard – risk of damage to the device. Disconnect the device from the power supply if power
input is above or below the specified input range.
Input Range
Power Supply Type
Minimum
Maximum
Internal Fuse Rating
ab
Maximum Power
Consumption
c
24 VDC
10 VDC
36 VDC
6.3 A(F)
48 VDC
36 VDC
72 VDC
3.15 A(T)
HI (125/250 VDC)
d
88 VDC
300 VDC
2 A(T)
HI (110/230 VAC)
d
85 VAC
264 VAC
2 A(T)
28 W
a
(F) denotes fast-acting fuse
b
(T) denotes time-delay fuse.
c
Power consumption varies based on configuration. 10/100Base-TX ports consume roughly 1 W less than fiber optic ports.
d
The HI power supply is the same power supply for both AC and DC.
Summary of Contents for RUGGEDCOM M2200
Page 4: ...RUGGEDCOM M2200 Installation Guide iv ...
Page 10: ...Preface RUGGEDCOM M2200 Installation Guide x Customer Support ...
Page 16: ...Chapter 1 Introduction RUGGEDCOM M2200 Installation Guide 6 Supported Fiber Optic Cables ...
Page 28: ...Chapter 2 Installing Device RUGGEDCOM M2200 Installation Guide 18 Wiring Examples ...
Page 42: ...Chapter 5 Technical Specifications RUGGEDCOM M2200 Installation Guide 32 Dimension Drawings ...