Technical Specifications
5.6 Operating Environment
Typical distance. The maximum segment length is greatly dependent on factors such as fiber quality, and the number of
patches and splices. Consult a Siemens sales associates when determining maximum segment distances.
5.6
Operating Environment
The RUGGEDCOM M2100F is rated to operate under the following environmental
conditions.
Ambient Operating
Temperature
-40 to 85°C (-40 to 185 °F)
Ambient Storage Tem-
perature
-40 to 85°C (-40 to 185 °F)
Ambient Relative Hu-
5% to 95%
Maximum Altitude
2000 m (6562 ft)
Measured from a 30 cm (12 in) radius surrounding the center of the enclosure.
Non-condensing
5.7
Mechanical Specifications
Weight
5.2 kg (11.5 lbs)
Ingress Protection
IP20
Enclosure
18 AWG Galvanized Steel
5.8
Dimension Drawings
Note
All dimensions are in millimeters, unless otherwise stated.
Note
Dimensional tolerances are in accordance with ISO 2768-mK, unless otherwise stat-
ed.
28
RUGGEDCOM M2100F
Installation Manual, 01/2020, C79000-G8976-1342-06