disallow access to the system. The
RDM-PC will indicate a logging error
message when a login attempt is made.

Up to 8 login names can be programmed. Use the

Prev 

and 

Next 

options to step through each login

name.

NOTE

:  Depending on the password you entered

at startup (password entered after typing
MENU), you may not have access to all
login names. 

For example

, if you entered

a password for entry number 7, you can
only access the login details for entry 7
and entry 8. The password for entry
number 1 has full access and can config-
ure details for all logins.

IF TROUBLE IS EXPERIENCED WITH the
RDM-MXL, please contact the Siemens Indus-
try, Inc., Technical Support Department at
(800) 248-7976.

U.S.A. - FCC EQUIPMENT LIMITATIONS:

• An FCC Part 68 compliant telephone cord

must be used.

• This equipment complies with Part 68 and

Part 15 of the FCC rules. On the back of the
RDM-MXL is a label that contains, among
other information, the FCC registration
number and ringer equivalence number (REN).
If requested, this information must be
supplied to the telephone company.

• The REN is used to determine the quantity of

devices which may be connected to the
telephone line. Excessive RENs on the
telephone line may result in the devices not
ringing in response to an incoming call. In
most, but not all areas, the sum of RENs
should not exceed 5. To be certain of the
number of devices that may be connected to
a line, as determined by the total RENs,
contact the local telephone company.

• If the RDM-MXL causes harm to the

telephone network, the telephone company
will notify you in advance that temporary
discontinuance of service may be required.
But if advance notice isn’t practical, the
telephone company will notify the customer
as soon as possible. Also, you will be advised
of your right to file a complaint with the FCC
if you believe it is necessary.

• The telephone company may make changes

in its facilities, equipment, operations or
procedures that could affect the operation of
the equipment. If this happens the telephone
company will provide advance notice in order
for you to make necessary modifications to
maintain uninterrupted service.

Summary of Contents for RDM-MXL

Page 1: ... a W t a l F 1 L X M M D R r o f r o t c e n n o c r e w o P 1 L X M M D R r o f r o t c e n n o c y a l e r n o i s i v r e p u S 1 l e b a l l a v o r p p a C C F l a n o i t i d d A The user will need to supply the following items Y T I T N A U Q M E T I 1 r o f 1 M D R o t y r e t t a B d n a L X M m o r f e l b a C 1 M I P L X M 1 r o f 1 M D R o t 1 M I P m o r f e l b a C e c a f r e t n I ...

Page 2: ...ter plate for the MOM 4 position This bracket has the same footprint as the MOM 4 and can accommodate 2 RMD MXL modules An assembly kit is included with the bracket that contains four nuts and eight screws Mount the bracket in the enclosure with four nuts at the positions labeled X in Figure 2 Refer to Figure 3 for wiring in the MXL MXLV enclosure The RDM MXL can also mount to a SYS3 MPFO adaptor ...

Page 3: ...3 Figure 3 Wiring the RDM MXL in an MBR 2 or MME 3 Enclosure ...

Page 4: ...4 Figure 4 Connecting the RDM MXL to the MXL MXL IQ System with MMB 2 SMB 2 Main Board Figure 5 Connecting the RDM MXL to the MXL MXL IQ System with MMB 1 SMB 1 Main Board ...

Page 5: ... MXL an additional adhesive label has been supplied In the case of the MXL Fire Indicator Panel this can be affixed to the door of the MXL cabinet 3 This equipment complies with Part 68 and Part 15 of the FCC rules On the back of the RDM MXL is a label that contains among other information the FCC registration number and ringer equivalence number REN If requested this information must be supplied ...

Page 6: ...ing MENU you will be prompted to enter a login password before you can configure the RDM MXL This password corresponds to the password configured for your login name The RDM MXL is shipped with the highest level level 1 password of PWORD1 After entering the correct password the main menu will scroll on the screen entering the incorrect password will exit the programming mode and revert the RDM MXL...

Page 7: ...cted supervision failure on Port A will transfer the supervision relays and will annunciate a Printer Offline trouble in condition on the MXL When failure occurs the RDM will get no further events from the MXL Relay Rating 30V 1A resistive 125 VAC 0 250A resistive Please note that the relays are not set to fail safe mode Both relays will energize when supervision failure is detected on any supervi...

Page 8: ... can be set if required by the telephone exchange 3 6 The communications parameters for Dialup Connections between RDM MXL and RDM PC should not be changed unless explicitly required 7 Show Diagnostics is a special mode which should only be activated by technicians in order to resolve modem communication problems at installa tion The default setting is set to NO 5 Dialup Logins Options 1 to 4 are ...

Page 9: ...alence number REN If requested this information must be supplied to the telephone company The REN is used to determine the quantity of devices which may be connected to the telephone line Excessive RENs on the telephone line may result in the devices not ringing in response to an incoming call In most but not all areas the sum of RENs should not exceed 5 To be certain of the number of devices that...

Page 10: ... be coordinated by a representative designated by the supplier Any repairs or alterations made by the user to this equipment or equipment malfunctions may give the telecommunications company cause to request the user disconnect the equipment Users should ensure for their own protection that the electrical ground connections of the power utility telephone lines and internal metallic water pipe syst...

Page 11: ...11 ...

Page 12: ...P N315 096325 4 Siemens Industry Inc Building Technologies Division Florham Park NJ Siemens Building Technologies Ltd Fire Safety Security Products 2 Kenview Boulevard Brampton Ontario L6T 5E4 Canada ...

Reviews: