How to pair transmitter and RDE-MZ6 

Make sure RDD100.1RF or RDE100.1RF (thermostat(s)/ 
transmitter(s)) are on your hands. 

 

Option 1: One transmitter for one zone on RDE-MZ6 

Learn 
Mode 

+

 

– 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

To pair one transmitter to one zone, proceed as 
follows: 

Transmitter setting: 

1) On the transmitter, enter the parameter 

settings (refer to section "Do you want to 
change parameters?"

 

in RDE100.1RFS or 

RDD100.1RFS Operating Instructions). 

2) Assign the transmitter to the following specific 

zone and ensure the parameter number is set 
as follows: 

Zone no. 1 on transmitter, adjust P19=1 
Zone no. 2 on transmitter, adjust P19=2 
Zone no. 3 on transmitter, adjust P19=3 
Zone no. 4 on transmitter, adjust P19=4 
Zone no. 5 on transmitter, adjust P19=5 
Zone no. 6 on transmitter, adjust P19=6 

RDE-MZ6 receiver setting: 

3) Power on the receiver. 
4) Press and hold the 

LEARN

 button of the 

respective channel/zone you want to learn on 
RDE-MZ6 for at least 3 seconds, then 
release it. 

5) The red and green LEDs flash alternately on 

the respective channel/zone to indicate this 
channel is in learning mode.  

Initiate learning: 

6)  On the transmitter, enter the parameter 

settings once again. 

7)  Proceed to parameter P20. Adjust the value 

to P20=1 (ON), then confirm. 

8)  During wireless learning, the LCD displays 

"rF" and "Lrn". Wait for time out and the 
transmitter exits the parameter settings. 

Successful wireless learning: 

9) The green LED flashes for 10 minutes to 

indicate that the paired channel has 
successfully completed wireless learning.  

Recommendation: 

10) 

Additional test to ensure the wireless signal 

is fine:

  

On the transmitter, change the operating 
mode by pressing 

Mode

 

or change the 

setpoint by pressing 

+

 or 

. On the paired 

channel, the green LED should flash for 3 
seconds before changing to constantly 
green. At the same time, observe your 
radiator, boiler or heater indication (if it has 
one) to ensure that it changed the operating 
mode. 

11) If step 9 or 10 is working fine, this means 

you have successfully paired the zone. 

Repeat the same steps above if you want to 
pair additional available transmitters individually. 

Unsuccessful wireless learning: 

12) If the channel fails to receive wireless data, 

the red LED starts to flash **. 

13) Repeat steps 1 to 10 until pairing is 

successful. 

Note:

  

Always start receiver learning before starting 
pairing with the transmitter. 

The units must be placed such that transmitter 
and received signals have limited external 
wireless interference. 

**In normal operation, if a drop in wireless 
communication occurs due to unforseeable noise, 
just leave the receiver and it will recover 
automatically. 

The pairs are saved even if there is a power shut 
down. Communication restarts automatically after 
several minutes without any user action.

 

Option 2: One transmitter for more zones on RDE-MZ6 

Learn 

Mode 

+

 

– 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 

 

 

To pair a single transmitter to 

more

 zones on 

the RDE-MZ6, proceed as follows:  

Transmitter setting: 

1) On the transmitter, enter the parameter 

settings (refer to section "Do you want to 
change parameters?"

 

in RDE100.1RFS or 

RDD100.1RFS Operation Instructions). 

2) Assign the transmitter to the following specific 

zone and ensure the parameter number is set 
as follows: 

Zone no. 1 on transmitter, adjust P19=1 

RDE-MZ6 receiver setting: 

3) Press and hold 

LEARN

 button of the 

multiple

 

channels/zones you want to learn on RDE-
MZ6 for at least 3 seconds, then release 
them. 

    Example: If you want to assign zone 1, 2 and 

3 of the RDE-MZ6 to zone 1 of the 
transmitter, press zone 1, 2 and 3 

LEARN

 

button on the receiver 

simultaneously

Observe that the LEDs of zone 1, 2 and 3 
flash alternately in red and green which means 
all 3 channels are in learning mode. 

Initiate learning: 

4) On the transmitter, enter the parameter 

settings once again. 

5) Proceed to parameter P20. Set the value to 

P20=1 (ON), then confirm. 

6) During wireless learning, the LCD displays 

"rF" and "Lrn". Wait for time out and the 
transmitter exits the parameter settings. 

Summary above: 

Zone 1 on the transmitter can control zone 1, 2 
and 3 of the RDE-MZ6. 

Note:

  

To check successful learning, refer to step 9-10 
of the previous section.

 

How to reset the ID of the zone? 

Reset

 

Reset all zones 

If the RDE-MZ6 is not in learning mode, press 
and hold the 

RESET 

button for more than 10 

seconds to reset all IDs of all 6 zones. 6 green 
LEDs flash for 5 seconds and then extinguish 
(recommended for first time setup). 

Reset one zone 

Press and hold the 

RESET

 button and the 

respective

 zone button for more than 10 

seconds. This only resets the specific zone. 
The green LED of the channel flashes for 5 
seconds and then extinguishes; the respective  
zone ID is reset. 