![Siemens Portable Radio Installation Manual Download Page 39](http://html.mh-extra.com/html/siemens/portable-radio/portable-radio_installation-manual_383758039.webp)
Certification
6.2 EMC and Environmental Type Tests
Test
Description
Test Levels
Severity Levels
IEC 60068-2-2
Dry Heat
Test Bd
85 °C (185
°F), 16 Hours
IEC 60068-2-30
Humidity (Damp
Heat, Cyclic)
Test Db
95% (non-
condensing), 55 °C
(131 °F), 6 cycles
IEC 60255-21-1
Vibration
2 g @ 10-150 Hz
Class 2
IEC 60255-21-2
Shock
30 g @ 11 ms
Class 2
30
RUGGEDCOM RS8000