12
Siemens Schweiz AG
A6V11689764_en--_c
GAMMA instabus
2020-12-18
Ambient conditions
Relative humidity
(non-condensing)
minimum
5 % r.h.
Relative humidity
(non-condensing)
maximum
90 % r.h.
Climatic resistance
EN 60721-3-3 class 3k5
Protection settings
Protection settings
Degree of pollution (according to IEC 60664-
1)
2
Overvoltage category (according to IEC
60664-1)
III
Protection type IP
IP20
Electrical safety, bus
Safety extra low voltage
Standard for which the device meets the
requirements (electrical safety)
EN 50491-3:2010
Standard for which the device meets the
requirements (EMV)
EN 50491-5-1
EN 50491-5-2
EN 50491-5-3
EN 61000-6-1
EN 61000-6-2
EN 61000-6-3
Reliability
Reliability
Failure rate (at 40°C)
489 fit