7
2
1 Main Precautions
When incorrectly used the MSK and MSKL are potentially dangerous machines.
Cleaning, maintenance or service must always be done by experienced operators, and with
the machine disconnected from the electricity supply.
NEVER use tools not belonging to the machine to help operation.
KEEP hands off the moving parts of the machine.
NEVER connect the power source with wet hands or wet clothes.
ALWAYS ground the machine properly
NEVER touch the blade No.06 (picture 01) even when it is not in use because its
edge is very sharp, it can cause serious cuttings.
NEVER adjust the cutting regulator (optional) No.12 (picture 01) with the blade in
motion.
NEVER use clothes with loosen sleeves specially near the wrist during the cutting
operation.
USE steel gloves during the cutting operation.
NEVER switch on the machine with one of its doors opened
NEVER spray water or other liquid substances directly at motor, power switch or
any other electrical components.
KEEP your working area clean and dry to prevent it from becoming sllipery.
ALWAYS install equipment in working area with adequate light and space away
from CHILDREN and visitors.
NEVER operate without all warning labels attached and owner/operator manual
available to operator.
NEVER leave unattended while operating.
STOP the machine immediately if you hear abnormal noises, of fear that injuries
may occur.
CONTACT your Distributor if you have any problems with the installation and
operation of this machine.
7.2 Upper bearing adjustments:
The purpose of this adjustment is to centralize the blade on the gear and avoid it
falling down.
First of all disconnect the machine from the electricity supply. Then loosen blade
No.06(picture 01) turning handle No.01 (picture 01) counter-clockwise.
Take out upper back lid by removing screws using the screwdriver. Loosen the
three screw-nuts No.01(picture 03) using a 10mm screw-wrench.
Using the screwdriver turn the screw-nut No.02 (picture 03) ¼ counter -clockwise if
t h e w h e e l i s i n c l i n e d t o w a r d s t h e f r o n t o r t u r n i t ¼
clockwise if it is inclined backwards. Tighten the three screw-nut No.01(picture 03)
previously loosen. Calibrate the blade according to pre-operation (5).
Turn the wheels manually to check if the blade is centralized, if it is not keep turning
the wheels until the blade is centralized.
7.3 Cutting Regulator:
The cutting regulator No.12 (picture 01) (optional) was designed to provide cuts
with the same thickness and also to protect the operator from getting injured.
To adjust the cutting regulator proceed as follows:
Turn locking knob No.15 (picture 01) counter-clockwise to be able to move the
cutting regulator to the left and right according to the distance you want to leave from it to the
blade.
Then turn the locking knob No.15 (picture 01) clockwise to fix the cutting regulator
in the desired position.
NOTICE TO OWNERS AND OPERATORS
The MSK and MSKL Mini Band Saws are designed to cut food products safely
and efficiently. Unless the operator is properly trained and supervised, however,
there is the possibility of a serious injury. It is the responsability of the owner to
assure that this machine is used properly and safely, strictly following the
instructions contained in this Manual and any requirements of local law.
02
03
01
Picture - 03