Milltronics WD600
Operating Instructions, 09/2016, A5E38964753_A
B
27
Technical data
8
8.1
Specifications
Accuracy
± 0.5% or better of totalization over 25 to 100% operating range
Accuracy subject to: On factory approved installations the belt scale systems totalized weight will be
within the specified accuracy when compared to a known weighed material test sample. The test
rate must be within the specified range of the design capacity and held constant for the duration of
the test. The minimum material test sample must be equivalent to a sample obtained at the test
flow rate for three revolutions of the belt or at least ten minutes running time, whichever is greater.
Load Cell
construction
nickel plated alloy steel or 17-4 PH (1.4568)
stainless steel
degree of protection
IP66 rated (nickel plated)
IP68 rated (stainless steel)
excitation
10 V DC nominal, 15 V DC maximum
output
2 mV/V excitation at rated load cell capacity
non-linearity
0.02% of rated output
hysteresis
0.02% of rated output
non-repeatability
0.01% of rated output
capacity
nickel plated maximum ranges: 10, 15, 20, 30, 50
kg
stainless steel maximum ranges: 6, 12, 30 kg
overload
150% of rated capacity
ultimate 300% of rated capacity
temperature
–40 to +65 °C (– 40 to +150 °F) operating range
–10 to +40 °C (–15 to +105 °F) compensated
Belt width
300 to 1200 mm (12 to 48")
Refer to Outline dimensions (Page 29)