Page 4
Milltronics MillPulse 600 – INSTRUCTION MANUAL
7ML19985DG02
Environmental
• location:
indoor/ outdoor
• altitude:
2000 m (6 562 ft) max.
• ambient temperature: -45 to 60 °C (-45 to 140 °F)
• max. relative humidity: 80%
• enclosure rating:
Type 4/NEMA 4, Type 4X/NEMA 4X, Type 6/NEMA 6, IP67
• installation category:
II
• pollution degree:
4
Weight
• 2 kg (4.4 lbs.)
Approvals
• CE, CSA
(C/US)
• EMC performance available upon request
Note:
• The use of approved watertight conduit hubs/glands is required for Type 4/NEMA 4,
Type 4X/NEMA 4X, Type 6/NEMA 6, IP67 (outdoor applications).