Siemens Milltronics Millpulse 600 Instruction Manual Download Page 1

Instruction Manual   September 2006

MILLPULSE 600

milltronics

Summary of Contents for Milltronics Millpulse 600

Page 1: ...Instruction Manual September 2006 MILLPULSE 600 MILLPULSE 600 milltronics ...

Page 2: ...urage users to purchase authorized bound manuals or to view electronic versions as designed and authored by Siemens Milltronics Process Instruments Inc Siemens Milltronics Process Instruments Inc will not be responsible for the contents of partial or whole reproductions of either bound or electronic versions While we have verified the contents of this manual for agreement with the instrumentation ...

Page 3: ...1 The Manual 1 Milltronics Millpulse 600 2 Specifications 3 Installation 5 Environment 5 Wiring 5 Interconnection 6 Loading 7 Operation 8 Dimensions 9 Application 10 Bucket Elevators 10 Shafts 10 Belt Conveyors 11 Screw Conveyors 11 Cleaning and Maintenance 12 ...

Page 4: ...ii ...

Page 5: ...tion 1 This warning symbol is used when there is no corresponding caution symbol on the product WARNING1 means that failure to observe the necessary precautions can result in death serious injury and or considerable material damage Note means important information about the product or that part of the operating manual In manual On product Description Protective Conductor Terminal Both direct and a...

Page 6: ...cuit card and magnet assembly potted in the probe body and comes complete with mounting flange and locknut Milltronics Millpulse 600 is connected in series with the PLC input or other load and acts as a switch opening and closing as the ferrous targets of the machinery being monitored pass in front of the probe 1 Milltronics Millpulse 600 is designed to work with Programmable Logic Control lers PL...

Page 7: ... second Voltage Drop 8 V Residual Current 1 5 mA Fuse 1A 250 V SLO BLO 4 5 x 14 5 mm not operator replaceable Switch Duration on 50 msec minimum off 50 msec minimum Operating Limit 600 pulses per minute maximum Operating Temperature 45 to 60 C 45 to 140 F Display red LED for switch status Construction probe body aluminum process mounting 2 NPSL connection box aluminum 3 4 NPT conduit entrance 4 sc...

Page 8: ... to 140 F max relative humidity 80 enclosure rating Type 4 NEMA 4 Type 4X NEMA 4X Type 6 NEMA 6 IP67 installation category II pollution degree 4 Weight 2 kg 4 4 lbs Approvals CE CSA C US EMC performance available upon request Note The use of approved watertight conduit hubs glands is required for Type 4 NEMA 4 Type 4X NEMA 4X Type 6 NEMA 6 IP67 outdoor applications ...

Page 9: ...ggested for easier removal or adjustment of the probe It is advisable to keep the Milltronics Millpulse 600 away from high voltage or current runs contactors and SCR drives Ensure that the switching current of the PLC input is above the residual current of the Milltronics Millpulse 600 and that the load resistance presented by the PLC input is low enough to ensure that the minimum operating curren...

Page 10: ...ipment must be protected by a 15A fuse or circuit breaker in the building installation A circuit breaker or switch in the building installation marked as the disconnect switch shall be in close proximity to the equipment and within easy reach of the operator WARNING All field wiring must have insulation suitable for at least 135 V fuse Operating Voltage jumper in 18 to 48 V AC DC jumper out 60 to ...

Page 11: ...7ML19985DG02 Milltronics MillPulse 600 INSTRUCTION MANUAL Page 7 Loading ...

Page 12: ...age generated from the probe coil is fed to a processing circuit The processing circuit controls a semiconductor switch that opens and closes in response to the incoming pulses The switch is normally open LED off and closes when a pulse is generated LED on The switch duration times are held to a minimum of 50 msec to give the PLC sufficient time to read the switch states The amplifier has been tun...

Page 13: ...e 10 32 screw 4 places Tighten screws to 1 1 to 1 7 N m 10 to 15 in lb of torque 226 mm 8 9 127 mm 5 locknut plated casing aluminum terminal block LED earth ground screw min M4 3 4 NPT conduit entrance 197 mm 7 75 DETAIL A MOUNTING 95 mm 3 75 dia probe clearance hole 6 mm 0 25 dia hole for 1 4 20 bolt or drill and tap on 114 mm 4 5 BCD 4 places 6 mm 0 25 dia hole for 1 4 20 bolt on 114 mm 4 5 BCD ...

Page 14: ...s where required Milltronics Millpulse 600 side mounting Milltronics Millpulse 600 front or back mounting ferrous buckets less than 75 mm 3 apart negligible side travel non ferrous buckets with ferrous bolts or buckets greater than 75 mm 3 apart Milltronics Millpulse 600 shaft paddle shaft key or keyway Milltronics Millpulse 600 ...

Page 15: ...nimum recommended Use series 300 stainless steel brass or aluminum Milltronics Millpulse 600 must not touch the plate if temperatures are in excess of 60 C 140 F ferrous blocks or spoked wheel Milltronics Millpulse 600 Milltronics Millpulse 600 idler end Window Detail Milltronics Millpulse 600 mounting bracket Milltronics Millpulse 600 with supplied flange and locknut conveyor troughing bracket wi...

Page 16: ...illtronics MillPulse 600 INSTRUCTION MANUAL 7ML19985DG02 Cleaning and Maintenance Millpulse 600 can be cleaned by wiping the enclosure exterior with a damp cloth No other maintenance is required for this device ...

Page 17: ...Notes Notes fm Page 1 Thursday October 11 2001 8 48 AM ...

Page 18: ...Notes Notes fm Page 2 Thursday October 11 2001 8 48 AM ...

Page 19: ...IQ300IX fm Page 5 Tuesday October 2 2001 1 43 PM ...

Page 20: ...ltronics Process Instruments Inc 1954Technology Drive P O Box 4225 Peterborough ON Canada K9J 7B1 Tel 705 745 2431 Fax 705 741 0466 Email techpubs smpi siemens com Siemens Milltronics Process Instruments Inc 2006 Subject to change without prior notice Printed in Canada ...