Appendix
A.2 Appendix II
BW500 and BW500/L
200
Operating Instructions, 12/2016, A5E33482052-AD
Span
●
a zero must be done prior
●
belt must be empty
●
test weight or chain must be applied
●
conveyor running at normal speed test reference (chain or weight applied)
●
moisture input not used
●
inclination will be used if feature is activated
PID Systems
●
zero and span criteria must be met
●
set controller (P400) to manual and adjust the output for 100% belt speed (using the 4 and 8
keys).
If the PID is not set to manual, the speed output will be the last value prior to starting the zero
or span calibration
●
shut off the prefeed to conveyor
●
In process where a prefeed device is included, it must be turned off to ensure that no material
is fed onto the belt.
A.2
Appendix II
Appendix II: Software Revision History
Software Revision
Date
Changes
2.00
April 30, 1999
•
Original software release
2.01
July 20, 1999
•
French language added
•
38400 baud rate option
removed
•
Span updated to reference
current zero value
•
NTEP printout added
•
Totalizer rollover updated to
1,000,000 for all resolutions
•
Added units to verification
totalizer printout
•
Error display updated to
toggle between error and run
mode
Summary of Contents for Milltronics BW500
Page 1: ...Operating Instructions Milltronics BW500 and BW500 L 12 2016 Edition Integrators ...
Page 12: ...Table of contents BW500 and BW500 L 10 Operating Instructions 12 2016 A5E33482052 AD ...
Page 14: ...Safety Notes BW500 and BW500 L 12 Operating Instructions 12 2016 A5E33482052 AD ...
Page 16: ...The Manual BW500 and BW500 L 14 Operating Instructions 12 2016 A5E33482052 AD ...
Page 48: ......
Page 154: ......
Page 218: ...Index BW500 and BW500 L 216 Operating Instructions 12 2016 A5E33482052 AD ...