Parameters
12.5 Online Calibration Options (P355 - P358)
BW500 and BW500/L
170
Operating Instructions, 12/2016, A5E33482052-AD
12.5.7
P365 Multispan
Note
Not available with BW500/L.
Select the span reference to be applied for determination of rate and totalization.
Entry:
1 = multispan 1 (MS1), for product or condition A
f
2 = multispan 2 (MS2), for product or condition B
3 = multispan 3 (MS3), for product or condition C
4 = multispan 4 (MS4), for product or condition D
5 = multispan 5 (MS5), for product or condition E
6 = multispan 6 (MS6), for product or condition F
7 = multispan 7 (MS7), for product or condition G
8 = multispan 8 (MS8), for product or condition H
Refer to Multispan and P270, Auxiliary Input Function (6).
12.5.8
P367 Direct Zero Entry
Directly enters the zero reference count.
Direct entry is intended for use when replacing software or hardware and it is not convenient to
perform an initial zero at that time (
f
= 0).
Refer to Recalibration (Page 67) for execution.
12.5.9
P368 Direct Span Entry
Directly enters the span reference count for the span selected, 1 to 8 (P368-01 to -08).
Note
BW500/L has one span entry possible, no indices will be presented.
Direct entry is intended for use when replacing software or hardware and it is not convenient to
perform an initial span at that time (
f
= 0).
Refer to Recalibration (Page 67) for execution.
Summary of Contents for Milltronics BW500
Page 1: ...Operating Instructions Milltronics BW500 and BW500 L 12 2016 Edition Integrators ...
Page 12: ...Table of contents BW500 and BW500 L 10 Operating Instructions 12 2016 A5E33482052 AD ...
Page 14: ...Safety Notes BW500 and BW500 L 12 Operating Instructions 12 2016 A5E33482052 AD ...
Page 16: ...The Manual BW500 and BW500 L 14 Operating Instructions 12 2016 A5E33482052 AD ...
Page 48: ......
Page 154: ......
Page 218: ...Index BW500 and BW500 L 216 Operating Instructions 12 2016 A5E33482052 AD ...
Page 219: ......