TABLE 1

NETWORK ADDRESS PROGRAMMING (SW1)

NETWORK ADDRESS PROGRAMMING

ADDR

87654321

ADDR

87654321

ADDR

8 76 5 43 2 1

ADDR

8 7 65 4 32 1

000

  ILLEGAL

064

OXOOOOOO

128

XOOOOOOO

192

XXOOOOOO

001

  ILLEGAL

065

OXOOOOOX

129

XOOOOOOX

193

XXOOOOOX

002

  ILLEGAL

066

OXOOOOXO

130

XOOOOOXO

194

XXOOOOXO

003
004
005
006
007
008
009
010
011
012
013
014
015
016
017
018
019
020
021
022
023
024
025
026
027
028
029
030
031
032
033
034
035
036
037
038
039
040
041
042
043
044
045
046
047
048
049
050
051
052
053
054
055

OOOOOOXX
OOOOOXOO
OOOOOXOX
OOOOOXXO
OOOOOXXX
OOOOXOOO
OOOOXOOX
OOOOXOXO
OOOOXOXX
OOOOXXOO
OOOOXXOX
OOOOXXXO
OOOOXXXX
OOOXOOOO
OOOXOOOX
OOOXOOXO
OOOXOOXX
OOOXOXOO
OOOXOXOX
OOOXOXXO
OOOXOXXX
OOOXXOOO
OOOXXOOX
OOOXXOXO
OOOXXOXX
OOOXXXOO
OOOXXXOX
OOOXXXXO

OOOXXXXX

OOXOOOOO
OOXOOOOX
OOXOOOXO

OOXOOOXX
OOXOOXOO
OOXOOXOX
OOXOOXXO
OOXOOXXX
OOXOXOOO
OOXOXOOX
OOXOXOXO
OOXOXOXX
OOXOXXOO
OOXOXXOX
OOXOXXXO
OOXOXXXX
OOXXOOOO
OOXXOOOX
OOXXOOXO
OOXXOOXX
OOXXOXOO
OOXXOXOX
OOXXOXXO
OOXXOXXX

067
068
069
070
071
072
073
074
075
076
077
078
079
080
081
082
083
084
085
086
087
088
089
090
091
092
093
094
095
096
097
098
099
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119

OXOOOOXX
OXOOOXOO
OXOOOXOX
OXOOOXXO
OXOOOXXX
OXOOXOOO
OXOOXOOX
OXOOXOXO
OXOOXOXX
OXOOXXOO
OXOOXXOX
OXOOXXXO

OXOOXXXX

OXOXOOOO
OXOXOOOX
OXOXOOXO
OXOXOOXX
OXOXOXOO
OXOXOXOX
OXOXOXXO

OXOXOXXX

OXOXXOOO
OXOXXOOX
OXOXXOXO

OXOXXOXX
OXOXXXOO
OXOXXXOX
OXOXXXXO
OXOXXXXX

OXXOOOOO
OXXOOOOX
OXXOOOXO
OXXOOOXX
OXXOOXOO
OXXOOXOX
OXXOOXXO

OXXOOXXX

OXXOXOOO
OXXOXOOX
OXXOXOXO

OXXOXOXX
OXXOXXOO
OXXOXXOX
OXXOXXXO
OXXOXXXX

OXXXOOOO
OXXXOOOX
OXXXOOXO

OXXXOOXX
OXXXOXOO
OXXXOXOX
OXXXOXXO
OXXXOXXX

131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183

XOOOOOXX

XOOOOXOO
XOOOOXOX
XOOOOXXO
XOOOOXXX
XOOOXOOO
XOOOXOOX
XOOOXOXO
XOOOXOXX
XOOOXXOO
XOOOXXOX
XOOOXXXO

XOOOXXXX

XOOXOOOO
XOOXOOOX
XOOXOOXO
XOOXOOXX
XOOXOXOO
XOOXOXOX
XOOXOXXO

XOOXOXXX

XOOXXOOO
XOOXXOOX
XOOXXOXO

XOOXXOXX
XOOXXXOO
XOOXXXOX
XOOXXXXO
XOOXXXXX

XOXOOOOO
XOXOOOOX
XOXOOOXO
XOXOOOXX
XOXOOXOO
XOXOOXOX
XOXOOXXO

XOXOOXXX

XOXOXOOO
XOXOXOOX
XOXOXOXO

XOXOXOXX
XOXOXXOO
XOXOXXOX
XOXOXXXO
XOXOXXXX

XOXXOOOO
XOXXOOOX
XOXXOOXO

XOXXOOXX
XOXXOXOO
XOXXOXOX
XOXXOXXO
XOXXOXXX

195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247

XXOOOOXX
XXOOOXOO
XXOOOXOX
XXOOOXXO
XXOOOXXX
XXOOXOOO
XXOOXOOX
XXOOXOXO
XXOOXOXX
XXOOXXOO
XXOOXXOX
XXOOXXXO
XXOOXXXX
XXOXOOOO
XXOXOOOX
XXOXOOXO
XXOXOOXX
XXOXOXOO
XXOXOXOX
XXOXOXXO
XXOXOXXX
XXOXXOOO
XXOXXOOX
XXOXXOXO
XXOXXOXX
XXOXXXOO
XXOXXXOX
XXOXXXXO

XXOXXXXX

XXXOOOOO
XXXOOOOX
XXXOOOXO

XXXOOOXX
XXXOOXOO
XXXOOXOX
XXXOOXXO
XXXOOXXX
XXXOXOOO
XXXOXOOX
XXXOXOXO
XXXOXOXX
XXXOXXOO
XXXOXXOX
XXXOXXXO
XXXOXXXX
XXXXOOOO
XXXXOOOX
XXXXOOXO
XXXXOOXX
XXXXOXOO
XXXXOXOX
XXXXOXXO
XXXXOXXX

056

OOXXXOOO

120

OXXXXOOO

184

XOXXXOOO

248

  ILLEGAL

057

OOXXXOOX

121

OXXXXOOX

185

XOXXXOOX

249

  ILLEGAL

058

OOXXXOXO

122

OXXXXOXO

186

XOXXXOXO

250

  ILLEGAL

059

OOXXXOXX

123

OXXXXOXX

187

XOXXXOXX

251

  ILLEGAL

060

OOXXXXOO

124

OXXXXXOO

188

XOXXXXOO

252

  ILLEGAL

061

OOXXXXOX

125

OXXXXXOX

189

XOXXXXOX

253

  ILLEGAL

062

OOXXXXXO

126

OXXXXXXO

190

XOXXXXXO

254

  ILLEGAL

063

OOXXXXXX

127

OXXXXXXX

191

XOXXXXXX

255

  ILLEGAL

O = OPEN (or OFF)   X = CLOSED ( or ON

)

Summary of Contents for MDACT

Page 1: ... programming refer to MXL Operation Installation and Maintenance Manual P N 315 092036 MXL IQ Operation Installation and Mainte nance Manual P N 315 093624 CSG M Manual P N 315 090381 and CSG M Version 11 05 Up date P N 315 099402 as applicable For FireFinder XLS programming refer to the FireFinder XLS Installation Operation and Mainte nance Manual P N 315 033744 and the Zeus Quick Start Manual P ...

Page 2: ...N position P7 P10 P5 P8 TB6 TB7 1 1 1 1 1 1 MDACT TB4 INSTALLED IN FIREFINDER XLS PANEL 1 2 3 4 5 6 7 8 9 10 11 12 13 1415 16 1 2 3 4 5 6 7 8 9 10 11 12 13 1415 16 P4 TB2 P2 XMI DO NOT USE WITH FIREFINDER XLS SEE XMI INSTALLATION INSTRUCTIONS P N 315 034870 MOM 2 FOR FIREFINDER XLS ONLY MODEL MOM 2 IS AVAILABLE REQUIRES MOUNTING PLATE MOM2 XMP TO 24V PSC 12 DO NOT USE WITH FIREFINDER XLS SEE XMI I...

Page 3: ...o the CSG M or Zeus configuration printout for the address of the module See Table 1 for MXL MNET and XLS HNET settings 2 Switch SW3 is factory set All switches must remain in the ON position 3 Set jumper plugs on JP4 to the M position 4 Set jumper plugs on P6 to the positions shown in Figure 3 Telephone Connectons Telephone Cord Installation Connect the primary phone line to the MDACT modu lar ja...

Page 4: ...T meets the requirements of UL 1950 1 2 3 6 7 8 R1 T1 4 5 R T RJ31X Module Full Modular Phone Jack To Dialer Connecting the Keypad to the MDACT NOTE The DCT P LCD Remote Keypad is used strictly for programming and debugging purposes only A DCT P LCD Remote Keypad can be used to operate the MDACT Communicator Plug the molex connector from the DCT P onto the connector pins on the MDACT board as show...

Page 5: ...MDACT Fire Communicator Available Reporting Formats Contact ID CID Is the preferred reporting format It provides a four digit account code followed by a three digit event code a two digit group number and a three digit contact number all of which are used to provide specific point identification SIA Security Industry Association SIA Digital Communication Standard The DACT provides level 1 compatib...

Page 6: ...vailable Report Format Radionics D6500 Radionics D6600 Sur gard SG SLR Osborne Hoffman Quick Alert Model II Ademco 685 Silent Knight SK9000 Contact ID q q q q q SIA 300 q q q SIA 110 q q q Figure 7 MDACT UL Listed Compatibility ...

Page 7: ...XOX OXXXOXXO OXXXOXXX 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 XOOOOOXX XOOOOXOO XOOOOXOX XOOOOXXO XOOOOXXX XOOOXOOO XOOOXOOX XOOOXOXO XOOOXOXX XOOOXXOO XOOOXXOX XOOOXXXO XOOOXXXX XOOXOOOO XOOXOOOX XOOXOOXO XOOXOOXX XOOXOXOO XOOX...

Page 8: ...P N 315 099351 6 Siemens Industry Inc Building Technologies Division Florham Park NJ Siemens Building Technologies Ltd Fire Safety Security Products 2 Kenview Boulevard Brampton Ontario L6T 5E4 Canada ...

Reviews: