background image

Extractor hood

LI60LBC24

en

User manual and installation instructions

Register your product on My Siemens and discover exclusive ser-
vices and offers.
siemens-home.bsh-group.com/welcome

The future moving in.

Siemens Home Appliances

Summary of Contents for LI60LBC24

Page 1: ... LI60LBC24 en User manual and installation instructions Register your product on My Siemens and discover exclusive ser vices and offers siemens home bsh group com welcome The future moving in Siemens Home Appliances ...

Page 2: ...on Only use this appliance For extracting cooking vapour In private households and in enclosed spaces in a domestic environment Up to an altitude of max 2000 m above sea level Do not use the appliance With an external timer 1 3 Restriction on user group This appliance may be used by children aged 8 or over and by people who have reduced physical sensory or mental abilities or inad equate experienc...

Page 3: ...eration is possible if the ap pliance is operated exclusively in circulat ing air mode WARNING Risk of fire Fatty deposits in the grease filters may catch fire Never operate the appliance without a grease filter Clean the grease filters roughly every 2 months Never work with naked flames close to the appliance e g flambéing Do not install the appliance near a solid fuel heating appliance e g wood ...

Page 4: ...unction with aluminium parts in the interior of the appliance may cause ex plosions Never use highly caustic alkaline or highly acidic cleaning agents In particular do not use commercial or industrial cleaning agents in conjunction with aluminium parts e g grease filter on extractor hoods 2 Avoiding material damage ATTENTION Condensate may cause corrosion damage To prevent condensation from buildi...

Page 5: ...es burning gas or other fuels not applicable to appliances that only discharge the air back into the room If the exhaust air is to be conveyed into a non functioning smoke or ex haust gas flue you must obtain the consent of the heating engineer re sponsible If the exhaust air is conveyed through the external wall a tele scopic duct should be used 5 Familiarising yourself with your appliance 5 1 Co...

Page 6: ... or highly acidic cleaning agents In particular do not use commer cial or industrial cleaning agents in conjunction with aluminium parts e g grease filter on extractor hoods WARNING Risk of electric shock An ingress of moisture can cause an electric shock Before cleaning pull out the mains plug or switch off the fuse in the fuse box Do not use steam or high pressure cleaners to clean the appliance...

Page 7: ...hen cleaning the grease filter in the dish washer light discolouration may occur This discoloura tion has no effect on the performance of the metal grease filters Requirement The grease filters have been removed Removing the grease filter Page 7 1 Observe the information regarding the cleaning agents 2 Place the grease filters loosely into the dishwasher Do not clean heavily soiled grease filters ...

Page 8: ...s applicable throughout the EU 10 Customer Service If you have any queries on use are unable to rectify faults on the appliance yourself or if your appliance needs to be repaired contact Customer Service Function relevant genuine spare parts according to the corresponding Ecodesign Order can be obtained from Customer Service for a period of at least 10 years from the date on which your appliance w...

Page 9: ...en installing the appliance 11 1 Scope of delivery After unpacking all parts check for any damage in transit and completeness of the delivery 11 2 Unit dimensions You will find the dimensions of the appliance here 11 3 Safety clearances Comply with the safety clearances for the appliance ...

Page 10: ...es to you Unrestricted operation is possible if the ap pliance is operated exclusively in circulat ing air mode Risk of poisoning from flue gases being drawn back in If an extractor hood with an open flued heat production source is installed the power supply for the extractor hood must be provided with a suitable safety switch Risk of poisoning from flue gases being drawn back in Do not emit the e...

Page 11: ...r supply with alternating current only via a properly installed socket with earthing The protective conductor system of the do mestic electrical installation must be prop erly installed Never equip the appliance with an external switching device e g a timer or remote control When the appliance is installed the mains plug of the power cord must be freely ac cessible If free access is not possible a...

Page 12: ...rs reduce the suction power and increase the fan noise Use an exhaust pipe that is made of non combust ible material To prevent condensate from returning fit the ex haust pipe with a 1 gradient from the appliance Round pipes Use round pipes with an inner diameter of 150 mm re commended or at least 120 mm 11 9 Instructions for the air extraction mode For air extraction mode a one way flap should be...

Page 13: ...ut the filter pull out fully 2 Undo the screw for the front end stop and pull it for wards as far as possible 3 Close the filter pull out and align it to the furniture 4 Pull out the filter pull out again 5 Retighten the screw for the front end stop Setting the air flow Requirement The grease filters have been removed Removing the grease filter Page 7 1 To set the air flow change the position of t...

Page 14: ...ausing damage do not bend the grease filters 4 Loosen the screw connection with the fitted unit 5 Remove the appliance 11 11 Air flow diagrams You can find the air flow diagrams below Basic ventilation adjustment diagram Static pressure drop pA L The A measured sound pressure level at 10 m sabin L The A measured sound pressure level relative to 1 pW WA Setting Airflow ...

Page 15: ...10 K11 K12 K factor 0 50 0 63 0 75 0 89 0 93 1 06 1 12 1 23 1 36 1 47 1 57 1 69 Basic ventilation size diagram Real pressure in the ventilation duct pA L The A measured sound pressure level at 10 m sabin L The A measured sound pressure level relative to 1 pW WA ...

Page 16: ...am Static pressure drop pA L The A measured sound pressure level at 10 m sabin L The A measured sound pressure level relative to 1 pW WA Cut away rings Existing opening of the reducing disc Without reducing disc Airflow K1 K2 K3 K4 K5 K factor 2 41 2 82 3 24 3 76 4 31 ...

Page 17: ...lation instructions en 17 Forced ventilation size diagram Real pressure in the ventilation duct pA L The A measured sound pressure level at 10 m sabin L The A measured sound pressure level relative to 1 pW WA ...

Page 18: ......

Page 19: ......

Page 20: ... 9001578323 9001578323 011027 en Manufactured by BSH Hausgeräte GmbH under the trademark licence of Siemens AG ...

Reviews: