background image

SIL24

 

ISTRUZIONI PER INSTALLAZIONE USO E MANUTENZIONE

    

INSTALLATION, USE AND MAINTENANCE INSTRUCTION

IT

GB

INFORMAZIONI COMMERCIALI PER I CONSUMATORI

COMMERCIAL INFORMATION FOR THE CONSUMER

INFORMAZIONI TECNICHE

TECHNICAL INFORMATION

Summary of Contents for SIL24

Page 1: ...I PER INSTALLAZIONE USO E MANUTENZIONE INSTALLATION USE AND MAINTENANCE INSTRUCTION IT GB INFORMAZIONI COMMERCIALI PER I CONSUMATORI COMMERCIAL INFORMATION FOR THE CONSUMER INFORMAZIONI TECNICHE TECHNICAL INFORMATION ...

Page 2: ...2 ...

Page 3: ...1 3 2 3 4 ...

Page 4: ...4 5 6 7 Fig 5 3 Fig 5 2 Fig 5 1 Fig 6 2 Fig 6 1 Fig 7 6 Fig 7 5 Fig 7 4 Fig 7 3 Fig 7 2 Fig 7 1 ...

Page 5: ...10 5 11 9 8 12 13 ...

Page 6: ...INDICE Avvertenze Versioni d uso Installazione Funzionamento Manutenzione IT 6 ...

Page 7: ...a aria dell apparecchio non deve essere collegata ad un con dotto usato per lo scarico di altri fumi quali impianti di riscaldamen to scaldabagni ecc Per l emissione all esterno dell aria rispettare le norme vigenti L alimentazione per il motore della centralina avviene tramite la cap pa posta in cucina Prima del collegamento elettrico assicurarsi che i valori di tensione dell abitazione corrispon...

Page 8: ...sione aspirante Usando la piastra superiore dis 5 1 posizionan dola sul soffitto effettuare 4 fori da 8 mm in cor rispondenza delle asole Nei fori eseguiti inserire i tasselli in plastica dis 5 1 A e fissare la piastra sul soffitto con le viti dis 5 1 B Successiva mente fissare la struttura inferiore dis 7 2 sulla cappa facendo coincidere i fori della stessa con le viti metriche saldate sul suppor...

Page 9: ...o della cappa al foro inferiore del deflettore Effettuare il collegamento elettrico Solo per ver sione con display sollevare il tubo inferiore fino a scoprire il cavo piattina che esce dal gruppo aspirante e collegarlo al cavo piattina del display Riabbassare il tubo inferiore facendo attenzione che entri correttamente nella sede della cappa aspirante Sollevare il tubo superiore dis 7 5 fino al so...

Page 10: ... OFF TEMPORIZZAZIONI Con l entrata in vigore dal 1 Gennaio 2015 dei nuovi regolamenti della Commissione Europea EU65 Energy label e EU66 Ecodesign ab biamo reso conforme i prodotti in base ai requisiti richiesti Tutti i modelli nelle versioni energy label dispon gono di una elettronica con funzioni di temporiz zazione delle velocità di aspirazione superiore a 650m h In effetti i modelli con motore...

Page 11: ...ll uso almeno una volta ogni due mesi Nel caso d uso dell apparecchio in versione fil trante è necessario sostituire il filtro carbone atti vo dis 10A periodicamente Il filtro di carbone si rimuove togliendo prima il filtro antigrasso dis 9 e poi tirando l apposita lin guetta in plastica del filtro carbone sgangiandolo dalla sua sede dis 10 Il filtro al carbone viene inserito nell operazione inver...

Page 12: ...CONTENTS Warnings Uses Installation Working Maintenance GB 12 ...

Page 13: ...an ces WARNINGS The air outlet of the appliance must not be connected to a flue which is used for exhausting other fumes from appliances such as a central heating boilers etc For the external exhausting of the fumes comply with the regula tions in force The motor of the peripheral exhausting group is powered by the coo ker hood placed in the kitchen Before connecting the cooker hood to the mains s...

Page 14: ...oles 8 mm each just next to the slots Insert the plastic dowels into the holes Fig 5 1 A and screw up the plate on the ceiling Fig 5 1 B Then fasten the lower structure Fig 7 2 on the hood by making its holes and the metric thread screws welded on the fan support coincide Fig 7 1 Insert the washers and nuts provided Fig 7 2 A and screw with an appropriate tool Connect the drainpipe to the power un...

Page 15: ...ipe until the ca ble strap coming out of the sucking unit is unco vered and connect it to the display cable strap Put down the lower pipe while paying attention it is being properly introduced into the hood Lift the upper tube Fig 7 5 up to the ceiling and insert the two self tapping screws Fig 7 5 D Warning Before connecting the flexible exhausting pipe to the motor make sure the stop valve which...

Page 16: ... Ecodesign regulations issued by the Eu ropean Commission which came into force as from January 1st 2015 our products have been adapted to comply with these new re quirements All of the models complying with the energy label requirements are equipped with new electroni cs including a timer device for suc tion speeds control when the air capacity ex ceeds 650m h Internal motor models with maximum a...

Page 17: ...pending on its use If the appliance is used in the filtering version the activated carbon filter fig 10A must be re placed periodically The carbon filter can be removed by first remo ving the grease filter as previously mentioned fig 9 and then releasing it as shown in fig 10 from the 10B filter Re insert the coal filter by operating in the opposite way The coal filter ne eds replacing depending o...

Page 18: ...marcato conformemente alla Diretti va Europea 2012 19 EC sui rifiuti da apparecchiature elettriche ed elettroniche WEEE IT The symbol on the product or on its packaging indicates that this product may not be treated as household waste Instead it shall be handed over to the applicable collec tion point for the recycling of electrical and electronic equipment By ensuring this pro duct is disposed of...

Page 19: ...19 ...

Page 20: ...90007000024 EM 01 21 ...