background image

en

Instructions for installation and use 

Extractor hood 

Summary of Contents for LC91KWW60B

Page 1: ...en Instructions for installation and use Extractor hood ...

Page 2: ...perfectly at its installation location This appliance is intended for domestic use and the household environment only The appliance is not intended for use outside Do not leave the appliance unattended during operation The manufacturer is not liable for damage which is caused by improper use or incorrect operation This appliance is intended for use up to a maximum height of 2000 metres above sea l...

Page 3: ...In any case consult your responsible Master Chimney Sweep He is able to assess the house s entire ventilation setup and will suggest the suitable ventilation measures to you Unrestricted operation is possible if the vapour extractor hood is operated exclusively in the circulating air mode Warning Risk of fire Fatty deposits in the grease filter may catch fire Regularly clean the grease filter Neve...

Page 4: ... are dangerous Repairs may only be carried out and damaged power cables replaced by one of our trained after sales technicians If the appliance is defective unplug the appliance from the mains or switch off the circuit breaker in the fuse box Contact the after sales service Risk of electric shock Do not use any high pressure cleaners or steam cleaners which can result in an electric shock Causes o...

Page 5: ...onmentally friendly manner ÇOperating modes OperatingmodesExhaust air mode Note The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventilate installation rooms which contain heat producing appliances Before conveying the exhaust air into a non functioning smoke or exhaust gas flue obtain the consent of the heating engineer responsible...

Page 6: ...ntrol panel III to select the fan setting you require Lighting The lighting can be switched on and off independently of the fan Touch the symbol Setting the brightness Press and hold the symbol until the desired brightness is reached Note Colour temperature settings are available in the Home Connect app provided the appliance has this function Boost function Switching on Touch the symbol Note Afte...

Page 7: ...l a fan setting lights up in the display This immediately stops fan run on Saturation display If the metal grease filters or activated charcoal filter are is saturated the corresponding symbols will flash once the appliance has been switched off Metal grease filter Activated charcoal filter Metal grease filter and activated charcoal filter and If you have not yet done so the metal grease filters s...

Page 8: ...brightness Press and hold the i symbol until the required brightness is reached Setting the colour 1 Switch off the fan 2 Touch the i symbol 3 Touch the A or symbol until the colour you require is selected Note Colour temperature settings are available in the Home Connect app provided the appliance has this function Boost function Switching on Touch the symbol Note After approximately 20 seconds t...

Page 9: ...l a fan setting lights up in the display This immediately stops fan run on Saturation display If the metal grease filters or activated charcoal filter are is saturated the corresponding symbols will flash once the appliance has been switched off Metal grease filter Activated charcoal filter Metal grease filter and activated charcoal filter and If you have not yet done so the metal grease filters s...

Page 10: ...a the hood controls on the hob If the extractor hood is being operated by means of the controls on the hood itself this mode of operation always has priority It is not possible to use the hood controls on the hob during this time Setting up a connection The hood must be switched off before you can connect the hob and extractor hood Connecting directly Make sure that the hob is switched on and is i...

Page 11: ...connection process You can cancel the process at any time by pressing the symbol To connect the extractor hood to your home network the hood and the light must be switched off 1 Press and hold the symbol until the D and Ù indicators start flashing 2 To start automatic login to your home network swipe right over settings area until D and flash 3 Press the WPS button on the router within the next 2 ...

Page 12: ...onnections you have saved on your home network and on Home Connect at any time Press and hold the and symbols until the D symbol goes out When the audible signal is switched on an audible signal sounds About data protection When your appliance is connected for the first time to a WLAN network which is connected to the Internet your appliance transmits the following categories of data to the Home C...

Page 13: ...Note Wash new sponge cloths thoroughly before use Note Follow all instructions and warnings included with the cleaning products Removing metal grease filter 1 Open the glass front slowly and fully Hold the glass front in the centre when doing so gripping it firmly 2 Open the lock and swing down the metal grease filter When you do this take hold of the metal grease filter from underneath with your ...

Page 14: ...nse them thoroughly Leave the metal grease filters to drain on an absorbent material In the dishwasher Note Slight discolouration may occur if the metal grease filters are cleaned in the dishwasher This discolouration has no effect on the performance of the metal grease filters Use normal domestic dishwashing detergents Do not clean heavily soiled metal grease filters together with cookware Place ...

Page 15: ... appliance You can make a note of the numbers of your appliance and the telephone number of the after sales service in the space below to save time should it be required Please be aware that a visit by an after sales engineer will be charged if a problem turns out to be the result of operator error even during the warranty period Please find the contact data of all countries in the enclosed custom...

Page 16: ...ilter for starter set LZ10AKU00 LZ10AKA00 Starter set for air recirculation mode angled hood without chimney Easy change filter for starter set LZ10AKT00 LZ10AKA00 Starter set for air recirculation mode with filter that can be regenerated flat hood with chimney LZ10AFS00 Starter set for air recirculation mode with filter that can be regenerated angled hood with chim ney LZ10AKS00 Starter set for a...

Page 17: ... hood is to be operated in air recirculation mode an optional accessory must be fitted To do this refer to the installation instructions provided The flue duct does not need to be fitted for air recirculation mode For additional optional accessories refer to the installation instructions provided The surfaces of the appliance are sensitive Avoid damaging them during installation PLQ PP PLQ PP PD P...

Page 18: ...tion location The surfaces of the appliance are easily damaged Avoid damaging them during installation The width of the extractor hood must correspond at least with the width of the hob For the installation observe the currently valid building regulations and the regulations of the local electricity and gas suppliers Warning Risk of fire Fatty deposits in the grease filter may catch fire The speci...

Page 19: ...al vacuum in the place where the heat producing appliance is installed does not exceed 4 Pa 0 04 mbar This can be achieved when the air needed for combustion is able to enter through openings that cannot be sealed for example in doors windows incoming exhaust air wall boxes or by other technical means In any case consult your responsible Master Chimney Sweep He is able to assess the house s entire...

Page 20: ...l KGeneral information GeneralinformationChecking the wall The wall must be level vertical and adequately load bearing The depth of the bore holes must be the same length as the screws The wall plugs must have a secure grip The enclosed screws and wall plugs are suitable for solid brickwork Suitable fasteners must be used for other structures e g plasterboard porous concrete poroton bricks The max...

Page 21: ...hood should be positioned and lightly mark where the lower edge of the appliance should be on the wall Determine where the middle should be based on the hob Note We recommend fitting the extractor hood such that the lower edge of the glass screen is in line with the lower edges of the adjacent wall hung cabinets Make sure that the specified safety clearances from the hob are complied with 2 Place ...

Page 22: ...hout a flue duct Installation Screw in the mounting supports for the extractor hood until they are hand tight use a spirit level to level the appliance and then screw the mounting supports in fully PP PP PP PP PP PP PP PP PP PP PP PP PP PP PP PP PP PP PP PP ...

Page 23: ...ints Attaching the flue duct If the extractor hood is to be operated in exhaust air mode a flue duct must be fitted The flue duct does not need to be fitted for air recirculation mode Warning Risk of injury From sharp edges during installation Always wear protective gloves while installing the appliance Warning Risk of electric shock Components inside the appliance may have sharp edges These may d...

Page 24: ...E XQGHU 7UDGHPDUN LFHQVH RI 6LHPHQV 9001158981 9001158981 990901 Valid within Great Britain Imported to Great Britain by BSH Home Appliances Ltd Grand Union House Old Wolverton Road Wolverton Milton Keynes MK12 5PT United Kingdom ...

Reviews: