7
Lighting
The lighting can be switched on and off independently of the
ventilation.
Press the
B
button.
Saturation display
If the metal grease filter and the activated charcoal filter are
saturated, the following numbers flash:
■
Metal grease filter:
‚
■
Activated charcoal filter:
ƒ
■
Metal grease filter and activated charcoal filter:
‚
and
ƒ
flash alternately
When this happens, do not delay cleaning the metal grease
filter or replacing the activated charcoal filter any further.
For instructions on how to clean the metal grease filter, refer to
the section
Cleaning and maintenance
.
Resetting a saturation indicator
Press and hold the
#
button until the saturation indicator no
longer flashes.
The saturation indicator is reset.
Resetting the saturation displays
1.
Press and hold the
#
button until the saturation indicator for
the metal grease filter no longer flashes.
The saturation indicator for the metal grease filter is reset.
2.
Press and hold the
#
button until the saturation indicator for
the activated charcoal filter no longer flashes.
The saturation indicator for the activated charcoal filter is
reset.
Switching over the display for circulating-air mode
For circulating-air mode, the electronic control display must be
switched over accordingly:
1.
Check that the extractor hood is connected and switched off.
2.
Press the
a
and
B
buttons at the same time until the
numbers
‚
and
ƒ
flash alternately.
The electronic control is switched over to circulating-air
mode.
Switching over the display for exhaust air mode
1.
Check that the extractor hood is connected and switched off.
2.
Press the
a
and
B
buttons at the same time until the
number
‚
flashes.
The electronic control is switched back to exhaust-air mode.
Temperature safety switch
The appliance is equipped with a temperature safety switch. If
excessive temperatures are measured at the appliance, the
appliance automatically switches to the highest fan level until
the temperature has dropped again.
■
If the hood is switched on, fan setting 3 is set automatically. If
the temperature falls again, the appliance switches back to
the previously selected fan setting.
■
If the hood is switched off, the appliance automatically
switches to fan setting 3. If the temperature falls again, the
appliance automatically switches off.
■
While the temperature safety switch is active,
£
is shown in
the display panel. The ventilation strength cannot be reduced
during this time.
Switching off the temperature safety switch
Press the
a
button until
£
no longer flashes in the display
panel. The temperature safety switch is switched off. The
ventilation is switched off.
Note:
If the ambient temperature of the display panel is still too
high after a short period of time, fan setting 3 is switched on
again.
Summary of Contents for LC66HA241T