background image

11

Electrical connection

This is what you have to do:

1.

Connect the green and yellow (Earth)

wire to the terminal in the plug marked
‘E’ or with the symbol (        ), or 
coloured green or green and yellow.

2.

Connect the blue (Neutral) wire to the

terminal in the plug marked ‘N’ or 
coloured black.

3.

Connect the brown (Live) wire to the 

terminal marked ‘L’, or coloured red.

The extractor hood 

should only be

connected to an earthed socket that has
been installed according to relevant
regulations.

If possible, site the earthed socket directly
behind the chimney panelling.

Electrical data:

Are to be found on the name plate inside
the appliance after removal of the filter
frame.

Before undertaking any repairs,

always disconnect the extractor hood from
the electricity supply.

Length of the connecting cable: 1.30 m.

If it is necessary to wire the extractor
hood directly into the mains:

The extractor hood should only be
connected to the electricity supply by a
properly qualified electrician.

A separator must be installed in the
household circuit. A suitable separator is a
switch that has a contact gap of more than
3 mm and interrupts all poles. Such
devices include circuit breakers and
contactors.

If the connecting cable for this 

appliance is damaged, the cable must be
replaced by the manufacturer or his 
customer service or a similarly qualified
person in order to prevent serious injury to
the user.

This extractor hood corresponds to EC
regulations concerning RF interference
suppression.

Electrical connection

WARNING: THIS APPLIANCE MUST BE
EARTHED
IMPORTANT: Fitting a Different Plug:

The wires in the mains lead are coloured in
accordance with the following code:

Green and Yellow

– Earth

Blue

– Neutral

Brown

– Live

If you fit your own plug, the colours of
these wires may not correspond with the
identifying marks on the plug terminals.

Weight in kg:

Exhaust air

Recirculating air

15,0

60 cm

90 cm

17,0

17,5

19,5

We reserve the right to construction changes within the 
context of technical development.

Prior to installation

Circulating-air mode

With activated carbon filter if exhaust-air
mode is not possible.

The complete installation set can be

obtained 

from specialist

outlets.

The corresponding accessory numbers can
be found at the end of these operating
instructions.

Preparing the wall

The wall must be flat and perpendicular.

Ensure that the wall is capable of
providing a firm hold for mounting
screws and plugs.

Summary of Contents for LC47650

Page 1: ...LC 47650 LC 47950 Operatingand installationinstructions ...

Page 2: ...2 min 650 min 550 Fig 1 GAZ Abb 1 ELECTRO ...

Page 3: ...f poisoning from combustion gases which are drawn back into the room An air intake exhaust air wall box by itself is no guarantee that the limiting value will not be exceeded Note When assessing the overall requirement the combined ventilation system for the entire household must be taken into consideration This rule does not apply to the use of cooking appliances such as hobs and ovens Unrestrict...

Page 4: ...or infirmed persons without supervision Young children should be supervised to ensure they do not play with the appliance If the connecting cable for this appliance is damaged the cable must be replaced by the manufacturer or his customer service or a similarly qualified person in order to prevent serious injury to the user Dispose of packaging materials properly see Installation instructions This...

Page 5: ... it catching fire increase but the efficiency of the extractor hood can also be adversely affected Important By cleaning the metal grease filters at appropriate intervals the possibility of them catching fire as a result of a build up of heat such as occurs when deep fat frying or roasting is taking place is reduced Cleaning the metal grease filters In normal operation 1 to 2 hours daily the metal...

Page 6: ...fore be disposed of as part of your normal domestic refuse 2 Clean the filters 3 Insert the clean filters back into the hood 3 Engage the lug 4 Insert the metal grease filters see Removing and inserting the metal grease filters Removing the filter 1 Remove the metal filters 2 Press in the lug and remove the activated carbon filter Inserting the filter 1 Remove the metal filters see Removing and in...

Page 7: ...on or a mild window cleaner to clean the canopy of the extractor hood Do not scrape off any dirt that has dried on but loosen it up with a damp cloth Do not use abrasive cleaning agents or sponges that could cause scratches Note Do not use alcohol spirit on plastic parts otherwise the surface may become matt in appearance Caution Ensure that the kitchen is ade quately ventilated Avoid naked flames...

Page 8: ...liance render it unusable You received your new appliance in a protective shipping carton All packaging materials are environmentally friendly and recyclable Please contribute to a better environment by disposing of packaging materials in an environmentally friendly manner Please ask your dealer or inquire at your local authority about current means of disposal The extractor hood can be used in ex...

Page 9: ...hat there is an adequate supply of fresh air which will be needed by the burner for combustion Safe operation is possible provided that the underpressure in the room where the burner is installed does not exceed 4 Pa 0 04 mbar This can be achieved if combustion air can flow through non lockable openings e g in doors windows and via the air intake exhaust air wall box or by other technical measures...

Page 10: ...he extractor hood unless there is already one fitted in the outlet duct or wall ventilation box If no one way flap was enclosed with the hood it can be obtained from a specialist retailer Installing the one way flap Snap the one way flap into the air pipe The two lightly sprung flaps must be able to move upwards If the exhaust air is going to be discharged into the open a telescopic wall box shoul...

Page 11: ...nd interrupts all poles Such devices include circuit breakers and contactors If the connecting cable for this appliance is damaged the cable must be replaced by the manufacturer or his customer service or a similarly qualified person in order to prevent serious injury to the user This extractor hood corresponds to EC regulations concerning RF interference suppression Electrical connection WARNING ...

Page 12: ...gas hob The bottom edge of the template equates to the lower edge of the extractor hood 4 Drill 4 x l 8 mm holes for the extractor hood and 2 x l 8 mm holes for the chimney panelling Insert plugs into the holes so that they are flush with the wall Note Take into account any special accessories that are going to be fitted 5 Attach the 2 enclosed spacers to the fixing bracket for the flue duct panel...

Page 13: ...e flue panelling together slots in the upper section must be pointing downwards and insert into the opening in the extractor hood Protect the cover panels from scratches for example by laying the template used for marking the wall over the top edge of the lower section 09 Connect up the air outlet pipe 10 Connect the hood to the electricity supply 13 Slide out the upper section and attach it to th...

Page 14: ...14 Notes ...

Page 15: ...15 361047 LZ51350 90 cm LZ50960 60 cm LZ50660 1 2 3 4 5 6 2x 10x 2x 7 ...

Page 16: ...9000 018 621 Printed in Germany 0704 Es Siemens Electrogeräte GmbH ...

Reviews: