4

fresh air is supplied. Toxic gases from the 

chimney or the extraction shaft are sucked 

back into the living space.

Adequate incoming air must therefore 

always be ensured.

An incoming/exhaust air wall box alone 

will not ensure compliance with the limit.

Safe operation is possible only when the 

partial vacuum in the place where the heat-

producing appliance is installed does not 

exceed 4 Pa (0.04 mbar). This can be 

achieved when the air needed for 

combustion is able to enter through 

openings that cannot be sealed, for 

example in doors, windows, incoming/

exhaust air wall boxes or by other technical 

means.

In any case, consult your responsible 

Master Chimney Sweep. He is able to 

assess the house's entire ventilation setup 

and will suggest the suitable ventilation 

measures to you.
Unrestricted operation is possible if the 

vapour extractor hood is operated 

exclusively in the circulating-air mode.

Risk of fire!

Grease deposits in the grease filter may 

catch fire.

Clean the grease filter at least every 

2 months. 

Never operate the appliance without the 

grease filter.

Risk of fire!

Grease deposits in the grease filter may 

catch fire. Never work with naked flames 

close to the appliance (e.g. flambéing). Do 

not install the appliance near a heat-

producing appliance for solid fuel (e.g. 

wood or coal) unless a closed, non-

removable cover is available. There must 

be no flying sparks.

Risk of fire!

Hot oil and fat can ignite very quickly. 

Never leave hot fat or oil unattended. 

Never use water to put out burning oil or 

fat. Switch off the hotplate. Extinguish 

flames carefully using a lid, fire blanket or 

something similar. 

Risk of fire!

When gas burners are in operation without 

any cookware placed on them, they can 

build up a lot of heat. A ventilation 

appliance installed above the cooker may 

become damaged or catch fire. Only 

operate the gas burners with cookware on 

them.

Risk of fire!

Operating several gas burners at the 

same time gives rise to a great deal of 

heat. A ventilation appliance installed 

above the cooker may become damaged 

or catch fire. Never operate two gas 

burners simultaneously on the highest 

flame for longer than 15 minutes. One 

large burner of more than 5 kW (wok) is 

equivalent to the power of two gas 

burners.

Risk of burns!

The accessible parts become very hot when 

in operation. Never touch hot parts. Keep 

children at a safe distance.

Risk of injury!

Components inside the appliance may 

have sharp edges. Wear protective gloves.

Risk of injury!

Items placed on the appliance may fall 

down. Do not place any objects on the 

appliance.

Risk of electric shock!

A defective appliance may cause electric 

shock. Never switch on a defective 

appliance. Unplug the appliance from the 

mains or switch off the circuit breaker in 

the fuse box. Contact the after-sales 

service.

Risk of electric shock!

Incorrect repairs are dangerous. Repairs 

may only be carried out and damaged 

power cables replaced by one of our 

trained after-sales technicians. If the 

appliance is defective, unplug the 

appliance from the mains or switch off the 

circuit breaker in the fuse box. Contact the 

after-sales service.

Risk of electric shock!

Do not use any high-pressure cleaners or 

steam cleaners, which can result in an 

electric shock.

Summary of Contents for LB59584M

Page 1: ... en Instruction manual Extractor hood LB59584M LB79585M LB89585M LB79585MGB ...

Page 2: ......

Page 3: ...d and by persons with reduced physical sensory or mental capabilities or by persons with a lack of experience or knowledge if they are supervised or are instructed by a person responsible for their safety how to use the appliance safely and have understood the associated hazards Children must not play with on or around the appliance Children must not clean the appliance or carry out general mainte...

Page 4: ...oil or fat Switch off the hotplate Extinguish flames carefully using a lid fire blanket or something similar Risk of fire When gas burners are in operation without any cookware placed on them they can build up a lot of heat A ventilation appliance installed above the cooker may become damaged or catch fire Only operate the gas burners with cookware on them Risk of fire Operating several gas burner...

Page 5: ... require it Clean and if required replace the filter at regular intervals in order to increase the effectiveness of the ventilation system and to prevent the risk of fire Put the lid on to reduce cooking steam and condensation Environmentally friendly disposal Dispose of packaging in an environmentally friendly manner Operating modes This appliance can be used in exhaust air mode or circulating ai...

Page 6: ... and switches off automatically after 30 minutes 1 Set the fan level 2 Press and hold the 2x button Fan run on is activated The button for this level flashes green Interval ventilation With interval ventilation the ventilation system switches on automatically at the lowest level for 10 minutes every hour The interval ventilation switches off after 24 hours Switching on Press and hold the 3J button...

Page 7: ...metal mesh grease filters These instructions apply to several appliance variants It is possible that individual features are described which do not apply to your appliance Risk of fire Grease deposits in the grease filter may catch fire Clean the grease filter at least every 2 months Never operate the appliance without the grease filter Notes Do not use any aggressive acidic or alkaline cleaning a...

Page 8: ...out the activated charcoal filter 5 Clean the appliance Fitting the activated charcoal filter only in circulating air mode 1 Insert the activated charcoal filter into the extractor hood 2 Guide the activated charcoal filter around the motor 3 Carefully slide the new activated charcoal filter into the retainer 4 Install the metal grease filters Installing the metal mesh grease filter 1 Insert the m...

Page 9: ...appliance is defective unplug the appliance from the mains or switch off the circuit breaker in the fuse box Contact the after sales service LED lights Defective LED lights must only be replaced by the manufacturer their customer service department or a licensed technician electrician Malfunction table Fault Possible cause Solution The appliance does not work The plug is not plugged into the mains...

Page 10: ... in the space below to save time should it be required Please be aware that a visit by an after sales engineer will be charged if a problem turns out to be the result of operator error even during the warranty period Please find the contact data of all countries in the enclosed customer service list To book an engineer visit and product advice Rely on the professionalism of the manufacturer You ca...

Page 11: ......

Page 12: ...0DQXIDFWXUHG E 6 DXVJHUlWH PE XQGHU 7UDGHPDUN LFHQVH RI 6LHPHQV 9001408505 9001408505 990830 ...