Siemens LB 23 Operating And Installation Instructions Download Page 3

3

Important notes:

The Instructions for Use apply to several
versions of this appliance. Accordingly,
you may find descriptions of individual
features that do not apply to your 
specific appliance.

This extractor hood complies with all 
relevant safety regulations.

Repairs

should be carried out by 

qualified technicians only.

Improper repairs may put the user at
considerable risk.

Do not use the appliance if damaged.

The appliance may be connected to

the mains by a qualified technician only.

The appliance is not intended for use

by young children or infirmed persons 
without supervision.
Young children should be supervised to
ensure they do not play with the appliance.

If the connecting cable for this 

appliance is damaged, the cable must be
replaced by the manufacturer or his custo-
mer service or a similarly qualified person in
order to prevent serious injury to the user.

Dispose of packaging materials 

properly (see Installation instructions).

This extractor hood is designed for

domestic use only.

Light bulbs must always be fitted

when the extractor hood is in use.

Defective bulbs should be replaced

immediately to prevent the remaining bulbs
from overloading.

Never operate the extractor hood 

without a grease filter.

Overheated fat or oil can easily catch

fire. 
If you are cooking with fat or oil, e.g. chips,
etc., never leave the cooker unattended.

Do not flambé food directly under the

extractor hood.

Risk of grease filter catching fire due

!

to flames.

Before using your appliance for the first
time, please read these Instructions for
Use carefully. They contain important
information concerning your personal
safety as well as on use and care of the
appliance.

Please retain the operating and 
installation instructions for a subsequent
owner.

The hotplates must always be covered

with a utensil.

Restrictions apply to the use of the

extractor hood over a solid-fuel burner
(coal, wood, etc.). (See Installation 
instructions).

Gas hobs / Gas cookers

Do not use all the gas hotplates 

simultaneously for a prolonged period 
(max. 15 minutes) at maximum thermal
load, otherwise there is a risk of burns if
the housing surfaces are touched or a risk
of damage to the extractor hood. If the 
extractor hood is situated over a gas hob,
operate the hood at maximum setting if
three or more gas hotplates are operated
simultaneously.

If you encounter a problem 

If you have any questions or if a fault
occurs, please call Customer Service. 
(See list of Customer Service 
representatives).
When you call, please quote the following:

Enter the relevant numbers into the box
above. The E-Nr. (product no.) and FD
(production date) are shown on the 
nameplate which can be seen inside the
extractor hood after the filter frame has
been detached.

E-Nr.

FD

Before using the first time

9000.022 567.qxd  06.09.2006  11:36 Uhr  Seite 3

Summary of Contents for LB 23

Page 1: ...Operating and installation instructions LB 23 LB 54 LB 75 ...

Page 2: ...king vapours Exhaust air mode The extractor hood fan extracts the kit chen vapours and conveys them through the grease filter into the atmos phere The grease filter absorbs the solid particles in the kitchen vapours The kitchen is kept almost free of grease and odours Circulating air mode An activated carbon filter must be fitted for this operating mode see Filters and maintenance Activated carbon...

Page 3: ...f you are cooking with fat or oil e g chips etc never leave the cooker unattended Do not flambé food directly under the extractor hood Risk of grease filter catching fire due to flames Before using your appliance for the first time please read these Instructions for Use carefully They contain important information concerning your personal safety as well as on use and care of the appliance Please r...

Page 4: ...ver the filter becomes increasingly inflammable The efficiency of the extractor hood can also be adversely affected Important Renewing the fleece filter at appropriate intervals prevents the possibility of it catching fire as a result of a build up of heat such as occurs when deep fat frying or roasting is taking place Renewing the fleece filter Under normal operating conditions 1 to 2 hours per d...

Page 5: ...l filter Under normal operating conditions 1 to 2 hours per day the metal grease filter will require cleaning after 8 to 10 weeks The filter can be cleaned in a dishwasher This can however cause slight discoloration Important Metal filters that are heavily saturated with grease should not be cleaned at the same time as any crockery etc If the filter mat is going to be cleaned by hand soak it first...

Page 6: ...rease filter by pulling it towards yourself 2 Clean the grease filters 3 Re insert the clean grease filters Removing and installing the activa ted carbon filter Extractor hoods with a filter mat 1 Remove the filter see grease filter The wire grille is no longer required when an activated carbon filter is installed 2 Place the activated carbon filter on the filter mat and clamp it in 3 Install the ...

Page 7: ...essories on the last page Use original filters only This will ensure optimum performance Disposing of the old activated carbon filter Activated carbon filters do not contain any pollutants They can be disposed of e g as residual waste Extractor hoods with two filter cartridges 1 Remove the filter cartridge See grease filter 2 Insert the screw through the wing nut and the sleeve and screw in the mi...

Page 8: ... off with a damp cloth Do not use scouring agents Warning Clean the control buttons with a mild detergent solution and a soft damp cloth only Painted aluminium and plastic surfaces Do not use scouring agents or abrasive sponges Do not use dry cloths Do not use corrosive acidic or alkaline cleaning agents Note Do not use alcohol spirit on plastic parts otherwise the surface may become matt in appea...

Page 9: ...off there is still a risk of burns 2 Remove the bulb ring with a screwdriver or similar tool 3 Replace the halogen light bulb conventional halogen bulb 12 Volt max 20 Watt G4 cap Caution Refer to for plug in lampholder Take hold of the bulb with a clean cloth 4 Re insert the bulb ring 5 Plug the appliance into the mains or switch it on at the fuse box Note If the light does not function check that...

Page 10: ...od must not be installed over a solid fuel cooker a potential fire hazard e g flying sparks unless the cooker features a closed non removable cover and all national regulations are observed The smaller the gap between the extractor hood and hotplates the greater the likelihood that droplets will form on the underside of the extractor hood Additional information concerning gas cookers When installi...

Page 11: ...low through non closeable openings such as in doors windows wall ventilation boxes or by alternative technical measures such as reci procally shutting the other device off etc If the air intake is inadequate there is a risk of poisoning from combustion gases which are drawn back into the room An air intake exhaust air wall box by itself is no guarantee that the limiting value will not be exceeded ...

Page 12: ...t page into the air pipe connector and then attach the exhaust air pipe 120 mm Ø extraction pipe Attach the exhaust air pipe directly to the air pipe connector Extractor hoods with 150 mm Ø air outlet 150 mm l extraction pipe Screw the reducing connector see optional accessories on the last page onto the air outlet Attach the extraction pipe to the redu cing connector 150 mm l extraction pipe Atta...

Page 13: ...ed person in order to prevent a hazardous situation Improper repairs may put the user at considerable risk Length of connection cable 1 20 m Electrical specifications The electrical specifications can be found on the rating plate inside the appliance when the filter frame has been removed Do not place hand in the air outlet This appliance complies with the EC radio interference suppression regulat...

Page 14: ...248 100 35 225 min 15 m in 15 500 3 16 352 3 Extractor hood with slide control 73 cm wide 1 and 2 motor 9 346 160 55 95 150 120 348 348 100 35 225 380 730 min 15 m in 15 16 352 3 700 3 Installation 310 160 150 120 95 80 60 496 9 230 250 380 530 346 310 160 150 120 95 80 60 696 9 230 250 380 730 346 ...

Page 15: ...ns 1 Loosen the screws 2 Hold the underside of the extractor hood Hold the underside of the extrac tor hood 3 Lower the extractor hood and remove Installation Installation spring Weight in kg Width 53 cm 1 motor Rocker switch Design changes with respect to technical development shall remain withheld Model Exhaust air Recircu lated air 5 0 6 3 1 motor Slide control 1 motor Slide control 53 cm 73 cm...

Page 16: ...ny 0904 Hi Siemens Elektrogeräte GmbH 280 530 280 530 280 530 380 530 730 380 530 730 LZ 72040 LZ 23000 LZ 73040 LZ 73050 461423 481051 095660 280 530 380 530 730 380 530 730 380 530 730 380 530 730 280 530 380 530 730 380 530 730 ...

Reviews: