English 

Installation Instruction 

 

 

Before starting to install and work with this device, please read the Safety 
Instructions 

Scope of delivery (fig.1): 

  IMKW6-10 Wireless Magnet C battery 3.6V ½ AA (a) 

  Magnet unit (b) 

  Screws: for detector (c), for magnet (d) 

  Plugs (e) 

  Jumper: for disabling the back tamper switch 

Installation 

Removing the front cover (Fig. 2-3) 

  Insert a screwdriver in the slot of the snap release and push gently, until the 

front cover is disengaged and you hear the opening click (Fig. 2). 

  Lift the Printed Circuit Board (Fig. 3b). 

Mounting the base (Fig. 4) 

 

 

Pay attention to the guidelines in the Installer Manual for mounting the 
IMKW6-10. 

  Break out the desired holes on the base for proper installation. 

  Mount the base to a fixed part of a door or window.  

  Install the Printed Circuit board back into the base. 

 

 

Use only the screws and plugs supplied. 

Setting operation Mode (external contacts) 

The unit can be configured for connecting one or more external contacts (NC) in 
series. This connection is protected by End Of Line 8.2k Ohm series resistor. The 
external wiring can be up to 15 m (certified up to 3 m). 
There are 3 operation modes for the IMKW6-10. The unit learns the mode of 
operation during power-up (insertion of the battery). 

Mode 

Setting at power-up 

External Contact 

Internal Contact 

Internal contact only 

open 

close 

External contact only 

Close with 8.2k EOL 

open 

Internal and external 

Close with 8.2k EOL 

close 

 

Disable back tamper switch 

The back tamper of the unit can be deactivated by inserting a jumper (Fig. 
3a).  

 

 

When the bypass jumper is set, the unit complies with EN50131 security 
grade 1. When the jumper is NOT set, the unit complies with EN50131 
security grade 2. 

 

Mounting the magnet (Fig. 5) 

  Mount the magnet on the moveable part of a door or window, aligned 

with the markings on the base of the detector. 

Installing the battery (Fig. 6-7) 

 

 

Risk of explosion if battery is replaced by an incorrect type. Use only 
batteries delivered by the supplier. 

  Insert the battery according polarity (-) (+) (Fig. 6). 

  Place the cover by inserting back in the appropriate closing pin. 

  Screw in the retaining screw (Fig. 7). 

Enrolment 

To enrol the IMKW6-10 on the SiWay panel/gateway, please follow the 
instructions of the corresponding installation/configuration manual. 

Testing 

Alarm transmission test 

 

Select the “Walk Test Mode” in the control panel as described in the 

installation/configuration manual in order to avoid a real alarm 
transmission. 

  Remove the magnet:  

The control panel will indicate each alarm transmission received. 

  Replace the magnet:  

The alarm message disappears. 

Maintenance and Service 

Check the detector regularly (at least once a year) to ensure that it is 
functioning correctly (by carrying out a walk test), that it is free of dirt, and 
that it is securely attached. If necessary, clean and /or secure the detector. 
 

Technical Data 

Data Protocol 

SiWay 

Wireless 

– range 

up to 300 m at open space 

Frequency band 

868 MHz   

Identification 

Unique ID serial number 

– 24 bit 

Event Transmission 

Alarm, Tamper, Supervision,  
Low Bat (at 2.4 V) 

Supervision Timing 

6~7 minutes (random) 

Detection Method 

Internal Reed Switch and External contacts 

Open/close distances (Fig. 5a) 
 
* Not tested by Telefication 

 

Close 

Open 

Wood / Plastic 

<17 mm 

>20 mm 

Metal (Iron)*  

<6 mm 

>10 mm 

Metal (Aluminium)* 

<9 mm 

>13 mm 

Concrete* 

<15 mm 

>20 mm 

Battery 

Lithium. 3.6 V Type: XL-050F, Size: 1/2AA 

Low battery threshold 

2.4 V 

EOL resistor 

8.2k 

Power Consumption 

Standby ~5 

Transmission ~16 mA 

Dimensions 

87 x 35 x 25 mm 

Weight (inc. battery) 

~40 g 

Environmental conditions: 

Operation temperature 

-10 to +50 °C 

Storage temperature 

-20 to +60 °C 

Humidity (EN60721) 

< 85% r.h., non condensing 

Housing protection EN60529, 
EN50102 

IP41 / IK02 

Siemens Security Products hereby declares that this product is in compliance with the 
essential requirements and other relevant provisions of Directive 1999/5/EC on Radio and 
Telecommunications Terminal Equipment (R&TTE) and 2004/108/EC on Electromagnetic 
Compatibility (EMC). 
The EC Declaration of Conformity is available from your Siemens sales office or: 
Siemens AB, Security Products, Englundavägen 7, SE-171 24 Solna, Sweden

 

EN 50130-4:2011, EN 50130-5: 2011, EN 50131-2-6:2008, 
EN 50131-5-3:2005+A1:2008 and R&TTE 
EN50131-2-6, Security Grade 2, Environmental Class II certified by: 
 
 
For more detailed instruction please refer to the manuals of the respective control panel or 
gateway.

 

Summary of Contents for IMKW6-10

Page 1: ...battery Fig 6 7 Risk of explosion if battery is replaced by an incorrect type Use only batteries delivered by the supplier Insert the battery according polarity Fig 6 Place the cover by inserting back in the appropriate closing pin Screw in the retaining screw Fig 7 Enrolment To enrol the IMKW6 10 on the SiWay panel gateway please follow the instructions of the corresponding installation configura...

Page 2: ...boitier à l aide de la vis fournie Fig 7 Programmation Pour programmer la centrale ou la passerelle SiWay de sorte qu elle identifie l IMKW6 10 suivez les instructions fournies dans le manuel d installation configuration correspondant Test Test de transmission de l alarme Sélectionnez le mode test de déplacement dans la centrale comme décrit dans le manuel d installation ou de configuration pour é...

Page 3: ...man na parte móvel da porta ou janela alinhada com as marcas na base do detector Instalar a bateria Fig 6 7 Existe risco de explosão caso a bateria seja substituída pelo tipo incorrecto Utilize apenas baterias entregues pelo fornecedor Insira a bateria de acordo com a polaridade Fig 6 Insira novamente a tampa na patilha de retenção apropriada Aperte o parafuso de fixação Fig 7 Registo Para regista...

Page 4: ...toru Instalace baterie obr 6 7 Nahradíte li baterii nesprávným typem může dojít k explozi Používejte pouze baterie dodávané výrobcem Vložte baterii pozor na správnou polaritu obr 6 Nasaďte zpět kryt ve správné pozici vzhledem k západce Zašroubujte přídržný šroub obr 7 Registrace Pokud chcete zaregistrovat IMKW6 10 do panelu brány SiWay postupujte podle pokynů v příslušném návodu na instalaci konfi...

Reviews: