en
Installation instructions
42
isolating switch must be integrated into the perman-
ent electrical installation in accordance with the in-
stallation regulations.
Electrically connecting an appliance without a
protective contact plug
Note:
Only a licensed professional may connect the ap-
pliance. Damage caused by incorrect connection is not
covered under the warranty.
An all-pole isolating switch must be integrated into the
permanent electrical installation according to the install-
ation regulations.
1.
Identify the phase and neutral conductors in the
socket.
The appliance may be damaged if it is not connec-
ted correctly.
2.
Connect the hob in accordance with the connection
diagram.
See the rating plate for the voltage.
3.
Connect the wires of the mains power cable accord-
ing to the colour coding:
‒
Green/yellow = Protective conductor
‒
Blue = Neutral conductor
‒
Brown = Phase (external conductor)
26.7 Installing the appliance
1.
Slide the appliance all the way in and centre it.
2.
Screw the appliance into place.
Note:
The gap between the worktop and the appliance
must not be closed by additional battens.
Thermal insulation strips must not be fitted to the side
panels of the surround unit.
26.8 Removing the appliance
1.
Disconnect the appliance from the power supply.
2.
Undo the securing screws.
3.
Lift the appliance slightly and pull it out completely.