30.4 Installation underneath a hob
If the appliance is installed under a hob, the following
minimum dimensions must be adhered to (including
substructure, if applicable).
The minimum worktop thickness a is based on the
required minimum clearance .
Hob type
a raised in mm
a flush in mm
b in mm
Induction hob
37
38
5
Full-surface induction hob
47
48
5
Gas hob
27
38
5
Electric hob
27
30
2
30.5 Installation in a tall unit
Observe the installation dimensions and the installation
instructions when installing in a tall unit.
¡
To ventilate the appliance, the intermediate floors
must have a ventilation cut-out.
¡
In order to ensure sufficient ventilation of the appli-
ance, there must be a ventilation opening of at least.
200 cm² in the base area. To do this, trim the base
panel or fit a ventilation grille. Ensure that the air ex-
change is guaranteed in accordance with the dia-
gram.
¡
If the tall unit has another back panel in addition to
the element back panels, this must be removed.
¡
Only fit the appliance up to a height which allows
accessories to be easily removed.