c01.fm
18. May 2006
optiPoint application module - XML Applications, Developer’s Guide
36
XML Object Reference
Form
Example
<?xml version="1.0" encoding="UTF-8" ?>
<IppDisplay>
<IppScreen ID="1" HiddenCount="0" CommandCount="1">
<IppForm ItemCount="3">
<Title>Test Newline Begin</Title>
<Url>http://subdomain.domain/path/program</Url>
<IppTextField MaxSize="30" Constraint="ANY" Default="TEXT"
Key="TF2">
<Label>First Text</Label>
<Text>abc123</Text>
</IppTextField>
<IppSpacer NewLine="BEGIN" />
<IppTextField MaxSize="30" Constraint="ANY" Default="TEXT"
Key="TF2">
<Label>Second Text</Label>
<Text>xyz890</Text>
</IppTextField>
</IppForm>
<IppCommand Type="SELECT" Priority="0">
<Label>Select</Label>
<ScreenID>1</ScreenID>
</IppCommand>
</IppScreen>
</IppDisplay>
Screenshot