HiPath Cordless Office
P31003-H3560-S403-54-7620, 09/05
11-6
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
cordless.fm
Power-Related Capacity Limits
11.5
Power-Related Capacity Limits
The number of base stations, their distance from the system, and the overall telephone config-
uration determine whether or not the output from the internal system power supply units is suf-
ficient or whether an additional supply is necessary.
●
HiPath 3800
If the correct number of LUNA2 modules was calculated, the system’s internal power sup-
ply unit provides sufficient power to supply the system configuration specified in Table 11-
1.
For information on how to calculate the number of LUNA2 modules required, see Page 3-
62.
●
HiPath 3750 and HiPath 3700
The system’s internal power supply unit provides sufficient power to supply the system
configuration specified in Table 11-3.
Table 11-3
HiPath 3750, HiPath 3700 - Maximum Number of SLA16N and SLMO24
Subscriber Line Modules Depending on the Number of Base Stations
Connected to SLC16N
HiPath 3750
HiPath 3700
Number of
SLC16N
Number of base stations
Number of
SLA24N
SLMO24
BS3/1
BS4
connected via
1xU
P0/E
BS2/2
BS3/3
BS4
connected via
2xU
P0/E
BC
0
0
0
7
1
16
8
5
2
32
16
3
Expansion cabinet
0
0
0
8
1
16
8
6
2
32
16
4
3
48
24
2
4
64
32
0