HiPath Cordless Office
Nur für den internen Gebrauch
A31003-H3590-S100-7-7620, 06/2012
11-6
HiPath 3000/5000 V9, Service documentation
cordless.fm
Power-Related Capacity Limits
11.4
Power-Related Capacity Limits
The number of base stations, their distance from the system, and the overall telephone config-
uration determine whether or not the output from the internal system power supply units is suf-
ficient or whether an additional supply is necessary.
●
HiPath 3800
If the correct number of LUNA2 modules was calculated, the system’s internal power sup-
ply unit provides sufficient power to supply the system configuration specified in Table 11-
1. For information on how to calculate the number of LUNA2 modules required, see Page
3-61.
●
HiPath 3550 and HiPath 3500
The following tables show which telephone configurations do not need an additional power
supply:
–
Table 11-3, depending on the number of BS3/1 and BS4 base stations connected to
the central CBCC/CBRC control board.
–
Table 11-4, depending on the number of BS3/1 base stations connected to SLC16N
and the number of BS4 base stations connected to SLC16N.
–
Table 11-5, depending on the number of BS3/3 base stations connected to SLC16N
and the number of BS4 base stations connected to SLC16N.
If extra telephone configurations are added to these, an additional power supply is needed
(Powerbox PB3000).
Table 11-3
HiPath 3550, HiPath 3500 - Maximum Number of Corded Telephones De-
pending on the Number of BS3/1 and BS4 Base Stations Connected to
CBCC or CBRC
Number
of BS3/1s and BS4s
connected via
1xU
P0/E
to
CBCC or CBRC
Maximum number of corded telephones
analog telephones
0
1-10
11-20
21-30
31-40
41-50
optiPoint 500
1
66
61
57
53
48
44
2
63
59
54
50
46
41
3
60
56
52
47
43
39
4
58
53
49
45
40
36
5
55
51
47
42
38
33
6
53
48
44
40
35
31
7
50
46
41
37
33
28